SIMATIC IPC677E 
Operating Instructions, 04/2019, A5E45117996-AA 

3

 

Preface 

 

 

Purpose of the operating instructions 

These operating instructions contain all the information you need for the installation, 

electrical connection, commissioning and expansion of the SIMATIC IPC677E and to 

maintain and repair the device. They are intended for the following qualified specialist 

personnel: 

 

Installation personnel 

 

Commissioning engineers 

 

IT administrators 

 

Service and maintenance personnel 

Basic knowledge required 

A solid background in electrical installation, personal computers, Microsoft operating 

systems and network technology is required to understand this manual. General knowledge 

in the field automation control engineering is recommended. 

Scope of the operating instructions 

These operating instructions are valid for all order versions of the SIMATIC IPC677E.  

History 

The following editions of these operating instructions have already been published: 

 

Edition 

Comment 

04/2019 

First edition 

Содержание SIMATIC IPC677E

Страница 1: ... 2 Mounting and connecting the device 3 Commissioning the device 4 Operating the device 5 Expanding the device and assigning device parameters 6 Maintaining and servicing your device 7 Technical specifications 8 Dimension drawings 9 Standards and approvals 10 Hardware descriptions A Technical support B Markings and symbols C List of abbreviations D ...

Страница 2: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Страница 3: ...ersonnel Commissioning engineers IT administrators Service and maintenance personnel Basic knowledge required A solid background in electrical installation personal computers Microsoft operating systems and network technology is required to understand this manual General knowledge in the field automation control engineering is recommended Scope of the operating instructions These operating instruc...

Страница 4: ...hat may be implemented please visit http www siemens de industrialsecurity Siemens products and solutions undergo continuous development to make them more secure Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used Use of product versions that are no longer supported and failure to apply the latest updates may incr...

Страница 5: ... Notes on mounting 28 2 4 Notes on ambient and environmental conditions 28 2 5 Information on I O devices 30 2 6 Notes on device and system extensions 31 3 Mounting and connecting the device 33 3 1 Preparing for mounting 33 3 1 1 Scope of delivery 33 3 1 2 Checking the delivery package 35 3 1 3 Identification data of the device 36 3 1 4 Mounting positions 37 3 1 5 Preparing the mounting cutout 39 ...

Страница 6: ... Integrating a new drive into the onboard RAID system 63 5 3 6 Data synchronization in the RAID system 64 5 4 Monitoring of the device 65 5 4 1 Monitoring functions 65 5 4 2 SIMATIC IPC DiagBase 66 5 4 3 SIMATIC IPC DiagMonitor 66 5 5 Remote maintenance of the device 67 5 5 1 Remote maintenance functions 67 5 5 2 SIMATIC IPC Remote Manager 68 5 6 Trusted Platform Module TPM 69 5 7 Buffer memory NV...

Страница 7: ...Applicability of technical specifications 111 8 2 General technical specifications 111 8 3 Current power consumption and power supply 113 8 3 1 Current power consumption of the system components 113 8 3 2 Technical specifications AC power supply AC 114 8 3 3 Technical specifications of direct voltage power supply DC 114 8 4 Electromagnetic compatibility 115 8 5 Ambient conditions 115 8 6 Technical...

Страница 8: ...ce fan supply X512 131 A 2 3 Supply for the power supply fan X515 132 A 2 4 Supply for the serial ATA drives X516 X521 132 A 3 Bus board 133 A 3 1 Design and principle of operation of the bus board 133 A 3 2 Pin assignment 12 V power supply connection for expansion cards 134 A 4 External interfaces 135 A 5 System resources 136 A 5 1 Currently allocated system resources 136 A 5 2 I O address alloca...

Страница 9: ...Instructions 04 2019 A5E45117996 AA 9 C Markings and symbols 147 C 1 Overview 147 C 2 Safety 147 C 3 Operator controls 147 C 4 Certificates approvals and markings 148 C 5 Interfaces 149 D List of abbreviations 151 D 1 Abbreviations 151 Index 155 ...

Страница 10: ...Table of contents SIMATIC IPC677E 10 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 11: ...ecting I O devices Switching the device on Supplied in printed form with the device Supplied data storage medium Current product infor mation Current notes on the device Changes compared with these Operating Instructions Online at SIMATIC IPC Documentation https support industry siemens com cs ww en view 109760621 Firmware BIOS de scription Information on Important firmware settings Firmware setti...

Страница 12: ... maintenance of SIMATIC Industrial PCs IPCs via a management PC Using Intel Active Management Technology Intel AMT Online at SIMATIC IPC Remote Manager http support automation siemens com WW view en 48707158 SIMATIC IPC Image Partition Creator Information on Backup and recovery of files directories drive partitions Online at SIMATIC IPC Image Partition Creator https support industry siemens com cs...

Страница 13: ...n ordered the features and illustrations described in this manual may differ from the features of your device Maximum industrial compatibility for 24 hour continuous use in industrial environments Maximum processor power in full configuration without loss of power throttling at up to 45 C ambient temperature Full metal enclosure with high electromagnetic compatibility EMC for use in industry Indep...

Страница 14: ...ration in removable drive bays in RAID systems Efficient event diagnostics through the SIMATIC IPC DiagBase or DiagMonitor monitoring software optional and signaling software OPC SNMP LAN Remote control and remote maintenance of the device through iAMT Intel Active Management Technology SSD as 2 5 SATA or M 2 NVMe Preventative data backup with the SIMATIC IPC Image Partition Creator High investmen...

Страница 15: ...with teaming capability 3 x LAN 10 100 1000 Mbps connections Service friendly equipment design modifications service Can be used flexibly in a wide variety of positions 1 3 Applications The device offers industrial PC systems for high performance and space saving applications in particular for manufacturers in the field of machine plant and control cabinet engineering Operating process and visuali...

Страница 16: ...ice SIMATIC IPC677E 16 Operating Instructions 04 2019 A5E45117996 AA 1 4 External design of the device 1 4 1 Side view right Removable drives Slots for removable drives RAID status indicators HDD alarm Battery compartment CMOS backup battery Front fan ...

Страница 17: ...After Power Failure has been set to Power On This means the device is switched on with the on off switch You then do not need to press the on off button 4 status LEDs Status display of the status indicators Page 19 COM1 X30 Serial interface DVI VGA X70 DVI D connection for CRT or LCD monitor with DVI port DisplayPort X71 X72 DisplayPort connection for digital monitor 3 Ethernet X1P1 X2P1 X3P1 X1P1...

Страница 18: ...current backward compatible with USB 3 0 2 0 1 1 Fixing screws for strain relief 100 V AC to 240 V AC Power supply connection On off switch You switch on the device with the on off switch This requires that the BIOS setup entry After Power Failure is set to Power On The on off switch does not isolate the device from the power supply Position ON when the symbol is pressed inward on the device Posit...

Страница 19: ...f Green Can be controlled by user program Yellow Can be controlled by controller program e g SoftPLC ERROR or L2 Off Red Flashing red Can be controlled by user program or controller program e g SoftPLC MAINT or L3 Off Yellow Red Can be controlled by controller program e g SoftPLC For additional information on controlling the LEDs or the NVRAM with a Windows operating system please refer to Buffer ...

Страница 20: ...ction with RAID and moni toring software Both off RAID is OK LED lights up red HDD1 is not OK LED lights up red HDD2 is not OK Both light up red RAID is not OK For information on locating the hard disk see section Displaying a defective hard disk of a RAID system in the RAID software Both flash RAID is synchronized Ethernet status indicators Status indicator Status Meaning of the status LED 1 Off ...

Страница 21: ...rating Instructions 04 2019 A5E45117996 AA 21 1 5 Internal design of the device 100 V AC to 240 V AC power supply Slots for removable drives Expansion card slots Heat sink of the processor Expansion card slots Motherboard Slots for memory modules Retainer for expansion cards ...

Страница 22: ...net go to Industry Mall https mall industry siemens com 2 Log in with your customer data 3 Select your user language 4 Go to your device in the product catalog tree structure on left Automation technology PC based Automation Industrial PC Box PC 5 In the tree structure on the left click on SIMATIC IPC677E 6 Select the Accessories tab in the display area SIEMENS spare parts services Information on ...

Страница 23: ...ctions of the SIMATIC IPC DiagBase software and in cludes The software for the stations to be monitored A library for creating user specific applications SIMATIC IPC Remote Manager The SIMATIC IPC Remote Manager enables the use of Intel Active Management Technology Intel AMT Remote access to SIMATIC IPCs enables for example sys tem or program errors to be corrected as well as firm ware BIOS and pr...

Страница 24: ...Product description 1 6 Accessories and spare parts SIMATIC IPC677E 24 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 25: ...lways fully disconnect the device from the supply voltage before performing work on the device or when the device will not be used over an extended period of time For control cabinet mounting Use a central easily accessible AC circuit breaker close to the device if possible When you install the device make sure that the power supply connector is easily accessible Risk of lightning strikes DANGER R...

Страница 26: ...g and to prevent the burn in effect Note Defective pixels in the display The manufacturing process of modern displays does not currently guarantee that all pixels of the display are perfect It is therefore inevitable that the display will contain a small number of defective pixels This does not limit the function in any way provided the defective pixels are not all in one location Use in industria...

Страница 27: ... device A damaged device can be under hazardous voltage and trigger a fire in the machine or plant A damaged device has unpredictable properties and states Death or serious injury could occur Avoid installing and commissioning a damaged device Label the damaged device and keep it locked away Send off the device for immediate repair Damage from condensation NOTICE Damage from condensation If the de...

Страница 28: ...ance with UL 61010 2 201 and EN 61010 2 201 are rendered void and there is a risk of overheating and personal injury You should observe the following information on ambient and environmental conditions Ambient and environmental conditions NOTICE Ambient conditions and chemical resistance Unsuitable environmental conditions can cause faults or damage the device Failure to comply nullifies the warra...

Страница 29: ...ation according to IEC EN UL61010 2 201 The device must be installed in such a way that it is part of a restricted access location e g a locked control cabinet control panel or server room Always maintain a minimum clearance of 100 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure High frequency radiation CAUTION Immunity to RF interference The device ...

Страница 30: ...nnected after the device has been disconnected from the power supply NOTICE Damage through regenerative feedback Regenerative feedback of voltage to ground by a connected or installed component can damage the device Connected or built in I Os for example a USB drive are not permitted to supply any voltage to the device Regenerative feedback is generally not permitted Note Checking the regenerative...

Страница 31: ...s disconnect the power plug before you open the device Only install device or system expansions designed for this device Observe the information on Electromagnetic compatibility provided in the technical specifications Contact your technical support team or the point of sale to find out which device and system expansions are suitable for installation NOTICE Open Equipment IEC EN UL61010 The device...

Страница 32: ...Safety instructions 2 6 Notes on device and system extensions SIMATIC IPC677E 32 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 33: ...ional DiagMonitor Image Partition Creator Power supply cable Supplied data medium On the supplied data medium read only you can find Software and tools to restore your ordered Microsoft Windows operating system Device drivers for installation in operating systems SIMATIC IPC677E Quick Install Guide SIMATIC IPC677E Operating Instructions Product information Firmware BIOS description Operating instr...

Страница 34: ...iew 109749498 en dl en Without operating system Installed software Monitoring software SIMATIC IPC DiagBase only with installed Microsoft Windows operating system SIMATIC Panel Driver and Tools only with installed Microsoft Windows operating system You will find the latest information on additional software for your device under Accessories and spare parts Page 22 Printed documents SIMATIC IPC677E...

Страница 35: ...int at the shipping company in charge Have the shipper confirm the transport damage immediately 2 Unpack the device at its installation location 3 Keep the original packaging in case you have to transport the unit again 4 Check the Scope of delivery Page 33 and any accessories you may have ordered for completeness and damage Please inform the delivery service immediately if the package contents ar...

Страница 36: ...delivered with Microsoft Windows operating system installed and is located on the rear of the device Example of COA label for the Microsoft Windows 10 operating system The Microsoft Windows 10 COA label has an additional security feature which conceals part of the product key The scratch off panel consists of a small transparent label with a silver colored scratch coating which was applied to conc...

Страница 37: ... with IEC EN UL 61010 2 201 is therefore a mandatory requirement for approval or operation The following mounting positions are permitted for the device For information on the maximum permissible ambient temperatures during operation refer to section Ambient conditions Page 115 Mounting positions according to UL61010 Note Operation in closed rooms The device is approved for operation in closed roo...

Страница 38: ...7996 AA Additional mounting positions according to UL61010 CSA 22 2 No 142 Note Operation in closed rooms The device is approved for operation in closed rooms only Note the Ambient conditions Page 115 Mounting in vertical format Note Mounting precautions The total power for USB and PCI PCIe expansions cannot exceed 30 W ...

Страница 39: ...to achieve the degrees of protection described below Note Read the information in the section Installation guidelines Page 41 Requirements for complying with degree of protection The degree of protection of the HMI device can only be guaranteed if the following requirements are met Material thickness at the mounting cutout for IP65 degree of protection or for enclosure type 4X type 12 indoor use o...

Страница 40: ... cutout Multi touch device 2 19 22 24 Width w 1 448 1 mm 513 1 mm 569 1 mm Height h 1 278 1 mm 315 1 mm 347 1 mm 1 Width and height must be interchanged for mounting in vertical format 2 Device with capacitive multi touch screen Installation depth Information on the overall depth is available in the section Dimension drawings Page 121 ...

Страница 41: ...t be securely fitted if you use fixing elements other than those specified below for mounting The device can fall and may be damaged Use only the specified fixing elements Note See the notes under Preparing the mounting cutout Page 39 For installation in control cabinets note the SIMATIC setup guidelines as well as the relevant DIN VDE requirements or the country specific regulations Ensure that t...

Страница 42: ...r the device the positions for the mounting clips shown below must be adhered to Requirement All packaging components and protective films have been removed from the device To install the device you need the mounting clips from the accessory kit The mounting seal on the front of the device is not managed Procedure Note If the mounting seal is damaged or protrudes from the device the guaranteed deg...

Страница 43: ... four spring fasteners latch fully into place on the upper and lower side of the device If necessary press the device again carefully into the mounting slot at the place that is not fully latched into position 3 Insert a mounting clip into the cutout provided on the device Note the correct position of the mounting clips 4 To secure the mounting clip tighten the grub screw with the slot screwdriver...

Страница 44: ...structions 04 2019 A5E45117996 AA 5 Repeat steps 3 and 4 until all mounting clips are securely fastened 6 Check the fit of the mounting seal Position of the mounting clips for multi touch devices Fasten the mounting clips to the positions as illustrated Device Position 24 display 22 display ...

Страница 45: ...Mounting and connecting the device 3 2 Mounting the device SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 45 Device Position 19 display ...

Страница 46: ...re rated for the maximum current input and ambient temperature of the device and meet the requirements of the following standards ANSI UL 498 and CSA C22 2 No 42 CSA C22 2 No 182 1 CSA C22 2 No 182 2 CSA C22 2 No 182 3 For countries other than the USA and Canada Supply voltage 230 V AC This device is supplied with a safety tested power cord and may only be connected to a grounded SCHUKO socket out...

Страница 47: ...contact over a large area and is marked with the following symbol Requirements For the equipotential bonding connection you require A T20 screwdriver An equipotential bonding cable with a minimum cross section of 2 5 mm2 Procedure 1 Connect the marked equipotential bonding connection M4 thread of the device with the equipotential bonding cable Make sure the equipotential bonding cable has contact ...

Страница 48: ... Otherwise there is a risk of fire and electric shock This can result in personal injury or property damage Ensure that the AC or DC connecting cables comply with the safety regulations of the country in which the device is installed and bear the marks required in each case Connect the protective conductor in accordance with the operating instructions WARNING Risk of electric shock The on off butt...

Страница 49: ...n under Country specific information on supply voltage Page 46 Screwdriver T10 Procedure 1 Make sure that the ON OFF switch is in position I Off to avoid unintentional startup of the device when you plug in the power cord 2 Connect the appliance connector to the device 3 Connect the power cable with the safety power outlet 4 If necessary install the enclosed cable grip ...

Страница 50: ... There is also a risk of fire if the device or connecting lines are damaged Always fully disconnect the device from the line voltage before performing work on the device or when the device will not be used over an extended period of time For control cabinet mounting Use an easily accessible central disconnect switch as near as possible to the device and connect the device to a protective conductor...

Страница 51: ...of the device when it is connected to the 24 V DC power supply 2 Switch off the external 24 V DC power supply 3 Connect the 24 V DC plug connector to the device Observe the correct polarity of the contacts Protective conductor Ground 24 V DC 4 If necessary install the enclosed cable grip 5 Secure the 24 V DC cable to the cable grip using a cable tie Note Reverse polarity protection The 24 V DC pow...

Страница 52: ...ation on the position of the interfaces is available in Side view left Page 17 2 Secure the cables with the strain relief See Connecting Ethernet USB strain relief Page 54 Connecting several monitors multi monitoring You will find up to three ports on the rear of the device for connecting monitors These ports are connected to the motherboard Parameter assignment is performed by means of the Contro...

Страница 53: ...system environments or networks Ethernet The integrated Ethernet port 10 100 1000 Mbps can also be used for communication and data exchange with automation devices such as SIMATIC S7 This functionality requires the SOFTNET S7 software package PROFINET PROFINET can be operated via Standard Ethernet interfaces RT Additional information Additional information is available in the catalog and the onlin...

Страница 54: ...device You need two cable ties to use the strain relief In addition to the Ethernet cables you can also use this strain relief to protect the four USB cables from inadvertent removal To secure the Ethernet strain relief you will need a T10 screwdriver Procedure 1 Secure the Ethernet USB strain relief with two oval head screws M3 to the device housing 2 Connect the network and USB cables with the d...

Страница 55: ...at Side view left Page 17 Commissioning the installed Windows operating system You can find information on first startup of the device and commissioning the installed Windows operating system in the documentation on the supplied data storage medium see Important instructions and manuals for operating the device Page 11 4 2 Configuring automatic switch on of device In the firmware settings you can ...

Страница 56: ...nnecting the device from the line voltage WARNING Risk of electric shock The on off button and on off switch do not fully disconnect the device from the mains There is also a risk of fire if the device or connecting lines are damaged Always fully disconnect the device from the line voltage before performing work on the device or when the device will not be used over an extended period of time For ...

Страница 57: ...not shut down safely NOTICE Data loss If a hardware reset is performed the device undergoes a hard reboot Data in the main memory is deleted Data on the hard disk drive may be lost The device may be damaged Perform a hardware reset only in the case of an emergency Procedure 1 Press the on off button for more than 4 seconds The unit switches off Information on the position of the buttons is availab...

Страница 58: ...Commissioning the device 4 3 Switching off the device SIMATIC IPC677E 58 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 59: ...You can find information on this in the detailed firmware BIOS description see Important instructions and manuals for operating the device Page 11 5 2 Drive configurations 5 2 1 RAID1 system The RAID1 system works on the principle of data mirroring on two drives In the event of a defective drive the RAID1 system can continue to work on the remaining drive and thus achieves a high level of availabi...

Страница 60: ...s The two hard disks required for a RAID1 system can be installed in SIMATIC IPC677E in the following locations For onboard RAID system Drives Page 79 5 3 3 Configure the onboard RAID system If you have ordered a device with an onboard RAID system the RAID system is already configured on delivery If you subsequently set up an onboard RAID system you will still have to configure it Requirements The...

Страница 61: ... Under Select Disc select the drives that you want to integrate into your RAID system and confirm your selection The mounted drive is provided with a check mark in the list You will find the assignment of the drive to the installation location in the drive cage after the drive name see 9 Select Create Volume The following screen shows the details on the RAID system just set up RAID Volume The onbo...

Страница 62: ... Start Intel Display status of the onboard RAID system faulty drive 1 Select the Status tab In the Storage System View area on the right side of the window you will find information on a defective drive a functioning drive Example display status of a RAID1 system Displaying details on the onboard RAID system 1 Select the Manage tab Details on your onboard RAID system are displayed in the Advanced ...

Страница 63: ...or a drive that has been set up as a replacement drive You can find notes on setting replacement drives in the controller documentation 1 Select Start Intel Intel Rapid Storage Technology 2 Select the Preferences menu 3 In the area Automatic Rebuild enable the option Auto rebuild on hot plug Configuring Manual mounting of a new drive before replacing a defective drive The RAID system is configured...

Страница 64: ...synchronization in the RAID system NOTICE Danger of incorrect operations on machine and plant delayed system reaction during data synchronization Data is synchronized if a drive fails The system can respond with a delay depending on the size of the drive and system load In extreme cases the execution of keyboard mouse or touch screen commands may be briefly delayed The result may be faulty operati...

Страница 65: ...Watchdog Monitoring of the system status and message to determine if a station is still operational If the watchdog is not addressed within a configured monitoring time a watchdog alarm is output A change to the monitoring time is effective immedi ately Depending on the setting the following actions are triggered Reset on Hardware reset is per formed Reset off No action is performed The device is ...

Страница 66: ...device Page 11 5 4 3 SIMATIC IPC DiagMonitor The SIMATIC IPC DiagMonitor monitoring software can be ordered optionally If a device is ordered with SIMATIC IPC DiagMonitor the software is included with the device in the delivery state Information on the software and documentation of SIMATIC IPC DiagMonitor can be found under SIMATIC IPC DiagMonitor https support industry siemens com cs ww en view 3...

Страница 67: ...e grated in the firmware This allows you to restart the IPC and change firmware BIOS settings remotely Remote Power Management SIMATIC IPCs can be turned on and off and restarted from another PC IDE redirection An ISO file on the Help Desk PC can be integrated and used on the SIMATIC IPC as a DVD drive An ISO file contains a memory image of the content of a CD or DVD structured in the ISO 9660 for...

Страница 68: ...ce of your device can be ordered as an option You can find information on the software and documentation of SIMATIC IPC Remote Manager under SIMATIC IPC Remote Manager http support automation siemens com WW view en 48707158 Important instructions and manuals for operating the device Page 11 See also SIMATIC IPC software http www automation siemens com mcms pc based automation en industrie pc erwei...

Страница 69: ...ted Platform Module in the corresponding firmware BIOS description see Important instructions and manuals for operating the device Page 11 5 7 Buffer memory NVRAM optional For applications to store data following a power failure motherboards feature battery buffered NVRAM If the supply voltage fails for more than 20 ms for the AC power supply or more than 5 ms for the DC power supply then you will...

Страница 70: ...Operating the device 5 7 Buffer memory NVRAM optional SIMATIC IPC677E 70 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 71: ... void For this reason please observe the information in Notes on device and system extensions Page 31 WARNING Malfunctions and electric shock Improper intervention in the device endangers operational reliability and may damage the device The results can be personal injuries and damage to the plant Take the following precautions Always disconnect the power plug before you open the device Close the ...

Страница 72: ...rovals apply only to expansion units which are released by SIEMENS Siemens disclaims any liability for impairment of functions caused by the use of third party devices or components Observe the installation instructions for the components UL approval of the device only applies when the UL approved components are used according to their Conditions of Acceptability Procedure 1 Remove the four marked...

Страница 73: ...u may experience contact problems malfunctions and difficulties with the assembly You can find the permitted dimensions for expansion cards under Dimension drawing of the expansion cards Page 124 See also Design and principle of operation of the bus board Page 133 6 2 2 Installing removing expansion cards Note Requirement for expansion cards You can find the permitted dimensions for expansion card...

Страница 74: ...OTICE Damage to the expansion card The expansion card can break if excessive force is used Do not apply any pressure Do not apply excessive force on the slider when you push it onto the expansion card 1 Remove the marked screw and swivel the cover to the side as shown Then remove the marked screws and the panels 2 Insert the expansion card into the relevant slot ...

Страница 75: ...expansion card with the card retainer 4 Fasten the slot cover of the expansion card see step 1 Notes on the allocation of resources The slots for the expansion cards come with exclusive interrupts The assignment of the PCI IRQ line to the PCI slot is explained in the chapter Bus board Page 133 Procedure Removal Proceed in reverse order of installation ...

Страница 76: ...t X200 DIMM2 2 Combination 1 4 GB 8 GB 16 GB 16 GB Combination 2 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 32 GB Combination 3 Combinations of three memory modules are not permitted Combination 4 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 4 GB 8 GB 16 GB 64 GB Usable memory modules DIMM DDR4 memory modules Memory transaction rate 2666 MT sec unbuffered without ECC Conditions of use of memory modules Me...

Страница 77: ...s Page 76 The device is open see Opening the Device Page 71 NOTICE Electrostatic discharge The electronic components on the assembled PCBs are highly sensitive to electrostatic discharge and can be destroyed by it Take appropriate precautionary measures See the notes under General safety instructions Page 25 Note When equipping the memory modules make sure that the memory modules are equipped in t...

Страница 78: ...rds applying slight pressure and press it until the locking snaps into place 4 Close the device Removing a memory module Note Also observe the order for equipping the memory modules described above when removing the memory modules 1 Loosen the locking mechanisms on the left and right of the slot 2 Remove the memory module from the slot 3 Close the device Display of the current memory configuration...

Страница 79: ...e drive and destroy data Only remove the removable tray from the device when the drive is inactive Observe the ESD guidelines Requirement An original spare part that is a drive approved for this device see notes in Accessories Hardware Page 22 If there is no RAID system The device is fully disconnected from the line voltage see Switching off the device Page 56 The device you wish to replace is ina...

Страница 80: ...contacts of the drive when you do this 5 Fasten the new drive with the screws to the base of the removable tray Only use the original screws 6 Fold the tray bracket out of the removable tray as far as it will go and slide the removable tray fully into the drive cage Ensure that the removable tray fits tightly in the drive cage 7 Close the tray bracket 8 Lock the removable tray with the key Note Th...

Страница 81: ...ce is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is an SSD of the same type see information under Accessories Hardware Page 22 Procedure Removal 1 Remove the marked screws 2 Remove the marked screws and place the SSD on its side ...

Страница 82: ...evice parameters 6 4 Drives SIMATIC IPC677E 82 Operating Instructions 04 2019 A5E45117996 AA 3 Remove the marked connectors 4 Remove the marked screws 5 Remove the carrier with the connectors remove the marked screws and take out the SSD ...

Страница 83: ...evice parameters 6 4 Drives SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 83 Procedure Installation Proceed in reverse order When connecting multiple drives observe the assignments of the port connections see PCB labeling ...

Страница 84: ...ed from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is a hard disk drive of the same type see information under Accessories Hardware Page 22 Procedure Removal 1 Remove the marked screws and place the hard disk drive on its side 2 Remove the marked screws and the drive ...

Страница 85: ...evice and assigning device parameters 6 4 Drives SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 85 3 Remove the marked connectors and remove the hard disk Procedure Installation Proceed in reverse order ...

Страница 86: ...rformed without shutting down the device The new drive can be integrated into the RAID system at operating system level with the RAID software Synchronization may take several hours depending on system load Replacing a defective drive in the RAID system 1 Determine which drive was reported by the RAID software as defective 2 Replace the appropriate drive see Drives Page 79 3 Replace the defective ...

Страница 87: ...th an length of up to 110 mm Phillips screwdriver P1 The drive bay module and the power supply are removed see Replacing the bus board Page 102 Procedure 1 Place the bus board on a suitable surface so that it lies flat and plane 2 Remove the marked screw 3 Lift the M 2 NVMe SSD slightly as shown and pull it out of the direct connector socket 4 Lay the thermal pad on the bus board in such a manner ...

Страница 88: ...rating Instructions 04 2019 A5E45117996 AA 5 Insert the M 2 NVMe SSD slightly inclined from above into the provided direct connector socket 6 Carefully push the M 2 NVMe SSD down and secure it with the screw 7 Install the bus board and then the drive bay module and the power supply again ...

Страница 89: ...of electric shock and electrocution 1 Switch off the system 2 Secure the system to prevent it switching back on 3 Check the system to ensure it is de energized 4 Ground and short the system 5 Cover or shield adjacent live parts These safety rules are based on the DIN VDE 0105 standard Note These safety steps must always be taken in the above order before any work on electrical systems Once work on...

Страница 90: ...isk drive 3 years Fan 3 years CMOS backup battery 5 years SSD Depends on the type of use 1 1 The interval for replacement of the flash drives SSD depends greatly on the type of use A specif ic interval cannot be given Note All drives are monitored with the SIMATIC DiagBase or SIMATIC DiagMonitor software tools on the basis of their Smart status As soon as the Smart status of the data storage mediu...

Страница 91: ...anted actions of the device or controller that are liable to cause personal injury or damage to the machinery Always switch off the device before you clean it Cleaning Agents NOTICE Damage to the HMI device caused by impermissible cleaning agents Impermissible and unsuitable cleaning agents may cause damage to the HMI device Use dish soap or foaming screen cleaner only as cleaning agents See the n...

Страница 92: ...irement The device is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is a fan of the same type see information under Accessories Hardware Page 22 Procedure Removal 1 Remove the two screws and remove the air guide pulling it up vertically 2 Loosen the pla...

Страница 93: ...and servicing your device 7 4 Removing and installing hardware SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 93 3 Remove the four plastic rivets on the enclosure 4 Take the fan out of the enclosure ...

Страница 94: ...stallation Proceed in reverse order of removal Note Install only a fan of the same type Note the correct mounting position of the fan Direction of flow Make sure that the blades bars of the fan housing are on the outside of the enclosure Run the power supply cable along the enclosure edge and fasten the cable The marked symbols show the rotation and flow direction of the fan ...

Страница 95: ...om the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part that is a fan of the same type see information under Accessories Hardware Page 22 Procedure Removal 1 Remove the four plastic rivets on the enclosure and remove the marked screw 2 Pull the power supply connector and remove the ...

Страница 96: ...ervicing your device 7 4 Removing and installing hardware SIMATIC IPC677E 96 Operating Instructions 04 2019 A5E45117996 AA 3 Take the power supply out of the enclosure 4 Remove the power supply fan and pull the fan plug ...

Страница 97: ...roceed in reverse order of removal Note Install only a fan of the same type Note the correct mounting position of the fan Direction of flow Make sure that the blades bars of the fan housing are on the outside of the enclosure Run the power supply cable along the enclosure edge and fasten the cable The marked symbols show the rotation and flow direction of the fan ...

Страница 98: ...fire do not solder on the cell body do not recharge do not open do not short circuit do not reverse polarity do not heat above 100 C and protect from direct sunlight moisture and condensation Requirement An original spare part that is a backup battery of the same type article number of lithium battery A5E00047601 CR2450 N see Accessories Hardware Page 22 You have noted the current firmware setting...

Страница 99: ...4 Removing and installing hardware SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 99 Procedure 1 Remove the marked screw 2 Remove the battery holder 3 Replace the battery reinsert the battery holder and fasten it with the screw ...

Страница 100: ...device is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 An original spare part i e a power supply of the same type see notes under Accessories Hardware Page 22 Procedure Removal 1 Remove the marked screw 2 Pull the power supply connector and remove the marked screws ...

Страница 101: ... Removing and installing hardware SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 101 3 Take the power supply out of the enclosure Procedure Installation Note Install only a power supply of the same type Proceed in reverse order ...

Страница 102: ...nt The device is disconnected from the mains and all connecting cables have been removed The device is open see important information regarding this under Opening the Device Page 71 Procedure Removal 1 Remove all modules from the slots 2 Remove the marked screws on the bus board 3 Remove the marked screws 4 Remove the back up battery holder see Changing the backup battery Page 98 ...

Страница 103: ... and servicing your device 7 4 Removing and installing hardware SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 103 5 Remove the marked screws and remove the top drive bay module including hard disk ...

Страница 104: ...servicing your device 7 4 Removing and installing hardware SIMATIC IPC677E 104 Operating Instructions 04 2019 A5E45117996 AA 6 Remove the marked hexagonal pins and remove the bottom drive bay module including hard disk ...

Страница 105: ... IPC677E Operating Instructions 04 2019 A5E45117996 AA 105 7 Remove the power supply see also Replace power supply Page 100 8 Pull the bus board from the motherboard as shown in the figure Procedure Installation Note Install only a bus board of the same type Proceed in reverse order ...

Страница 106: ...r Opening the Device Page 71 The memory modules have been removed The air guide has been removed see chapter Replacing device fans Page 92 An original spare part i e a processor of the same type Only an approved processor is permitted to be installed on the motherboard NOTICE Damage to the processor If the installed processor is operated with a higher clock frequency than permitted it can be destr...

Страница 107: ... all the way back The bay releases the processor 3 Remove the processor by grabbing the marked rails on the side Do not touch the processor and its connections in the process see ESD guidelines under General safety instructions Page 25 Note The contact springs of the socket are highly sensitive to mechanical damage e g caused by an incorrectly inserted CPU or foreign objects and their entire surfa...

Страница 108: ...t again Make sure that the bay covers the screw 6 Press the lever all the way down and lock it again NOTICE Damage to the processor due to excessive force The locking mechanism may be stuck The locking mechanism is damaged while being pressed down The processor is not correctly locked in place by the bay The result may be malfunctions Do not use excessive force Tilt the lever back again and try ag...

Страница 109: ...ion of the device Page 11 7 5 2 Installing software and drivers On the supplied USB stick read only you will find the Documentation and Drivers suite which you use to install all supplied software and drivers Requirements A Windows operating system is booted Internet Explorer 11 or higher is installed Scripts and ActiveX controls are enabled in the browser Procedure 1 Connect the supplied USB flas...

Страница 110: ...131 7 7 Backing up data and changing partitions We recommend the SIMATIC IPC Image Partition Creator software to back up data under Windows which supports the hardware of the IPC677E as of version 3 5 3 You will find detailed information on this software in SIMATIC IPC Image Partition Creator https support industry siemens com cs ww de view 21766418 en Please also observe the information in Techni...

Страница 111: ...documenta tion Dimensions IPC677E W x H x D in mm 19 22 24 464 x 294 529 x 331 585 x 363 Weight 19 22 24 9 5 kg 10 5 kg 12 5 kg Supply voltage AC Nominal 100 V AC to 240 V AC 15 10 wide range Supply voltage DC 1 Nominal 24 V DC 20 20 SELV 1 Input current AC Continuous current up to 2 5 A up to 50 A for 1 ms at startup Input current DC Continuous current up to 8 A up to 14 A for 20 ms at startup Li...

Страница 112: ...e is designed for environments with pollution degree 2 Transient overvoltages Device is designed for connection to supply with overvoltage category II transient overvoltages up to 2500 V 1 The device must only be connected to a 24 V DC power supply which meets the require ments of safe extra low voltage SELV according to IEC EN DIN EN UL 601010 2 201 A protective conductor must also be used see ch...

Страница 113: ...ces for panel PC 2 41 A Individual currents max permis sible 14 A 14 A 12 5 A 0 3 A 1 Base device includes motherboard processor memory both fans CF 2 Depends on the selected device configuration 3 2 USB3 1 type C high current and 4 USB3 1 low current 4 The total power for individual PCI PCIe slots cannot exceed 25 W The total power for USB and PCI PCIe slots cannot exceed 30 W Typical power value...

Страница 114: ...ltage in the normal and buffered mode are identified with the classification VFI SS or VI SS Power supply characteristics AC power supply Input data Voltage Nominal 100 240 V AC 15 10 wide range Frequency Nominal 50 Hz to 60 Hz min 47 Hz to max 63 Hz sinusoidal Continuous current Max 2 5 A Starting current load independent to 50 A for 1 ms Active power 176 W Apparent power 190 VA Output data Volta...

Страница 115: ...0 V 10 KHz to 80 MHz 80 AM to IEC 61000 4 6 Immunity to magnetic fields 100 A m 50 60 Hz according to IEC 61000 4 8 8 5 Ambient conditions See the note in Applicability of technical specifications Page 111 Climatic ambient conditions Temperature Operation 1 Tested according to IEC 60068 2 1 IEC 60068 2 2 IEC 60068 2 14 0 C to 45 C Storage transport 20 C to 60 C Gradient max 10 C h in operation 20 ...

Страница 116: ...MB cache VT iAMT Main memory Expansion options 4 up to 64 GB DDR4 SDRAM equipment see ordering docu mentation Buffer memory 512 KB NVRAM Expansion slots Maximum 2 expansion slots Maximum bandwidth of PCI slots Rev 2 3 133 Mbps Maximum bandwidth of PCI slots Rev 3 0 8 GT s 985 Mbps bandwidth per lane Max permissible power loss per slot Total power consumption all voltages may not exceed 25 W Expans...

Страница 117: ...80 pixels 1920 x 1080 pixels 1920 x 1080 pixels Possible colors Up to 16 7 million Brightness control Yes value range 0 to 99 1 0 backlighting off Backlighting Half Brightness Life Time MTBF12 LED 50000 h LED 30000 h LED 30000 h Pixel error class in accordance with ISO 9241 307 II Power consumption 25 W 25 W 32 W 1 Via SetBrightness dialog 9 to 99 10 to 100 via SetBrightness command line call 0 to...

Страница 118: ... LAN Remote Boot and the following Teaming modes are supported Adapter Fault Tolerance AFT Adaptive Load Balancing ALB IEEE 802 3ad Dynamic Link Aggregation DLA Static Link Aggregation SLA Switch Fault Tolerance SFT COM1 RS232 115 kbps max 9 pin SUB D male Free slots for expansion cards see Motherboard Page 129 Versions with 2 and 5 PCI e cards 1 For unique labeling the Ethernet ports are numbered...

Страница 119: ...Multi language user interface MUI 5 languages English German French Spanish Italian You can find information on ordered Microsoft Windows operating systems under Important instructions and manuals for operating the device Page 11 Partitioning in the delivery state for Microsoft Windows 10 Windows 10 boots in UEFI mode in the delivery state The following table lists the partitioning for disks 200 G...

Страница 120: ...Technical specifications 8 10 Technical specifications of the operating systems SIMATIC IPC677E 120 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 121: ...SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 121 Dimension drawings 9 9 1 Dimension drawing of 19 device with capacitive multi touch screen ...

Страница 122: ...rawings 9 2 Dimension drawing of 22 device with capacitive multi touch screen SIMATIC IPC677E 122 Operating Instructions 04 2019 A5E45117996 AA 9 2 Dimension drawing of 22 device with capacitive multi touch screen ...

Страница 123: ...rawings 9 3 Dimension drawing of 24 device with capacitive multi touch screen SIMATIC IPC677E Operating Instructions 04 2019 A5E45117996 AA 123 9 3 Dimension drawing of 24 device with capacitive multi touch screen ...

Страница 124: ...ension drawings 9 4 Dimension drawing of the expansion cards SIMATIC IPC677E 124 Operating Instructions 04 2019 A5E45117996 AA 9 4 Dimension drawing of the expansion cards Short PCI or PCIe expansion card ...

Страница 125: ...rence emis sion Immunity to interfer ence Industry EN 61000 6 4 EN 61000 6 2 AC devices are compliant with EN 61000 3 2 Transient currents and EN 61000 3 3 Voltage fluctuation and Flicker 2014 35 EU Electrical equipment for use within specific voltage limits Low Voltage Directive Conformance with this standard has been verified according to EN 61010 2 201 relevant only for AC devices 2011 65 EU Re...

Страница 126: ...s meets the requirements of ISO 9001 This has been certified by DQS the German society for the certification of quality management systems Certificate no 001323 QM08 Software license agreements If the device is supplied with preinstalled software you must observe the corresponding license agreements 10 3 UL approval The following approvals are available for the device Underwriters Laboratories UL ...

Страница 127: ...e required to correct the inter ference at his own expense Shielded Cables Shielded cables must be used with this equipment to maintain compliance with FCC regulations Modifications Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Conditions of Operations This device complies with Part 15 of the FCC Rules Operation is subj...

Страница 128: ...EN 61000 6 4 Generic standards Emission standard for industrial environments 10 7 Eurasion Customs Union EAC Identification for Eurasion Customs Union EAC Eurasian Conformity Customs union of Russia Belarus and Kazakhstan Declaration of conformity according to Technical Regulations of the Customs Union TR CU 10 8 Korea KOREA This product meets the requirements of Korean certification This product ...

Страница 129: ...rboard consists of these main components Processor and chip set four slots for memory modules internal and external interfaces and the Flash BIOS Slots for memory modules Processor Slots for bus boards Technical features of the motherboard Technical features of the motherboard can be found under Technical specifications of the motherboard Page 116 ...

Страница 130: ...3 X523 2 Status LEDs 9 Power supply X800 18 SATA 0 Port2 X526 3 2xUSB 2 0 X13 10 USB 2 0 X15 IPC677E only 19 BIOS Recovery X594 4 COM1 X30 11 USB 2 0 X17 IPC677E only 20 CPU fan X513 5 DVI X70 12 LVDS X9 IPC677E only 21 RAM DIMM1 2 X190 6 2x DPP X71 X72 13 Backlight X4007 22 RAM DIMM1 1 X19 7 LAN 1 X1 P1 14 1x USB 2 0 X562 23 RAM DIMM2 2 X200 LAN 2 X2 P1 15 PS fan X52 24 RAM DIMM2 1 X20 LAN 3 X3 P...

Страница 131: ...for this not included in scope of delivery contact your local SIEMENS contact person Serial ATA Internal Serial ATA max 2 4 drives operable Connection for PS serial ATA Internal Power supply for serial ATA Connection for PS fan Internal Power supply for CPU fan 4 pin male connector Connection for device fan Internal Power supply for device fan 4 pin male connector Backup battery Internal Power sup...

Страница 132: ... 3 Supply for the power supply fan X515 Pin Name Meaning 1 GND Ground 2 12 V Switched voltage supply 3 PG1 FAN_CLK Clock signal 4 PWM PWM signal A 2 4 Supply for the serial ATA drives X516 X521 Pin Name Meaning 1 12 V Output power supply 2 GND Ground 3 GND Ground 4 5 V Output power supply 5 3 3 V Output power supply ...

Страница 133: ...s The bus board is available in the following designs Information on pin assignment is available in the sections below Version 1 IPC677E 2 slots Slot 1 2 PCI 12 V power supply connection see Pin assignment 12 V power supply connection for expan sion cards Page 134 Version 2 IPC677E 2 slots Slot 1 PCI Express x16 Slot 2 PCI Express x4 mechanical x16 12 V power supply connection see Pin assignment 1...

Страница 134: ...supply connection see Pin assignment 12 V power supply connection for expan sion cards Page 134 A 3 2 Pin assignment 12 V power supply connection for expansion cards Pin Name Meaning Input Output 1 12 V 1 12 V voltage Output 2 GND Ground 3 GND Ground 4 5 V 1 5 V voltage Output 1 max permitted current 1 A with this power demand the total power demand for the PCI slots are not allowed to be exceeded...

Страница 135: ...rface specifications and the intended use Interface Connector Description Assignment COM1 X30 9 pin standard plug 12 V USB 3 1 X2 A B X4 A B USB3 Port 0 1 USB2 Port 0 1 interface side 3 3 V 900 mA up to 10 Gbps USB 3 1 type C X61 X63 USB3 Port 0 1 USB2 Port 0 1 interface side 5 V 1 5 A to 3 0 A up to 10 Gbps Ethernet 1 2 and 3 X4 X2 Xn RJ45 up to 1 Gbps DVI D X70 24 pin DVI D female connector 3 3 ...

Страница 136: ...dress allocation The following tables describe the system resources in the factory state of the device Static area I O address hex Size byte Description of the basic function Alternative function From To 0000 001F 32 DMA controller 0020 0021 2 Programmable interrupt controller 0022 0023 2 Not used 0024 0025 2 Programmable interrupt controller 0026 0027 2 Not used 0028 0029 2 Programmable interrupt...

Страница 137: ...therboard resources 0081 0091 17 DMA controller 0092 0092 1 Motherboard resources 0093 009F 13 DMA controller 00A0 00A1 2 Programmable interrupt controller 00A2 00A3 2 Not used 00A4 00A5 2 Programmable interrupt controller 00A6 00A7 2 Not used 00A8 00A9 2 Programmable interrupt controller 00AA 00AB 2 Not used 00AC 00AD 2 Programmable interrupt controller 00AE 00AF 2 Not used 00B0 00B1 2 Programmab...

Страница 138: ...d for COM1 or COM2 03F0 03F7 8 Not used 03F8 03FF 8 COM1 Can be deactivated in setup then free Reserved for COM1 or COM2 Dynamic range resources are managed by means of Plug and Play functionality I O address hex Size byte Description of the basic function Alternative function From To 0400 0453 84 Motherboard resources 04D0 04D1 2 Programmable interrupt controller 0680 069F 32 Motherboard resource...

Страница 139: ...assignment of the interrupts in the delivery state of the device Y Interrupt in APIC mode Z BIOS Default Interrupt in PIC mode e g DOS 1 Host PCI IRQ A to H is assigned to IRQ 16 to 23 permanently in APIC mode Host PCI IRQ A to H will be automatically assigned IRQ 0 to 15 by BIOS in PIC mode A specific assignment can not be enforced ...

Страница 140: ...pt assignment of the slot connectors on the bus board 1 Host PCI IRQ A to H will be assigned IRQ 16 to 23 permanently in ACPI mode Host PCI IRQ A to H will be automati cally assigned IRQ 0 to 15 in PIC mode A specific assignment can not be enforced Y Interrupt in APIC mode Z BIOS Default Interrupt in PIC mode e g DOS ...

Страница 141: ... 21 1 PCI Express slot 16 1 3 1 Requirement The modules in the PCI slots each require only one interrupt 2 Requirement VGA and PCIexpress do not require an interrupt 3 Requirement VGA does not require an interrupt and Ethernet1 is disabled Assigning exclusive interrupts in the firmware PIC mode The interrupts are automatically assigned to the slots at system startup due to the default settings in ...

Страница 142: ... FFFF 32 K VGA graphics text refresh memory 000C 0000 000C BFFF 48 K VGA BIOS expansion 000C 0000 000C FFFF 64 K VGA BIOS Always allocated or reserved 000E 0000 000F FFFF 2 64K DMI data System BIOS Op tions ROMs PXE RAID 0010 0000 CFFF FFFF 3 2 GB System memory 4 GB memory configuration Depends on memory configuration EFFF F000 EFFF FFFF 4 K Motherboard resources F000 0000 F3FF FFFF 64 M Motherboa...

Страница 143: ...on siemens com mcms aspa db en Pages default aspx Training center http sitrain automation siemens com sitrainworld AppLang en Industry Mall https mall industry siemens com TIA Selection Tool http w3 siemens com mcms topics en simatic tia selection tool When contacting your local contact person or Technical Support please have the following information at hand Article number of the device MLFB BIOS...

Страница 144: ...ion refer to the monitor operating instructions The power cord or the monitor cable is not connected Check whether the power cord has been properly connected to the monitor and to the system unit or to the grounded shockproof outlet Check whether the monitor cable has been properly connected to the system unit and to the monitor If the monitor screen still remains dark after you have performed the...

Страница 145: ... Problems when booting the device Problem Cause Remedy After changing the hard disk the system does not boot from the RAID array RAID array does not have highest boot priority BIOS setup Boot menu Permit RAID system in the boot priority Give RAID system top boot priority After changing the drive un used is indicated for the rele vant SATA port System was booted without func tioning hard disk The r...

Страница 146: ... RAID is activated Install the software again with the help of the sup plied USB sticks B 2 4 Problems when using expansion cards Problem Cause Remedy The device crashes during startup I O addresses are assigned twice Hardware interrupts and or DMA channels are assigned twice Signal frequencies or signal levels are not adhered to Different pin assignment Check your computer configuration If the co...

Страница 147: ...s The symbols on your device may vary in some details from the symbols shown in the following tables C 2 Safety Symbol Meaning Symbol Meaning Warning observe the supplied docu mentation Lock is closed Attention radio equipment Lock is open Disconnect the power plug before opening Opening for Kensington lock Attention ESD Electrostatic sensitive device Warning of hot surface C 3 Operator controls S...

Страница 148: ...rmation in the operating instructions for your device Symbol Meaning Symbol Meaning Approved for Australia and New Zea land Marking for the Eurasian Customs Union Approved for China Test mark of Factory Mutual Re search CE markings for European countries Marking of Federal Communications Commission for the USA EFUP Environment Friendly Use Period marking for China Approved for Korea Test mark of t...

Страница 149: ...ductor terminal PS 2 keyboard interface Connection for functional earthing equipotential bonding line Multimedia Card Reader DisplayPort interface Smart Card Reader DVI D interface Line In LAN interface not approved for con necting WAN or telephone Line Out Serial interface Microphone input USB port Universal Audio Jack USB 2 0 high speed port Headphone output USB 3 0 super speed port USB 3 1 Supe...

Страница 150: ...Markings and symbols C 5 Interfaces SIMATIC IPC677E 150 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 151: ... with all applicable EC directives CLK Clock pulse Clock signal for controllers CMOS Complementary Metal Oxide Semiconduc tors Complementary metal oxide semiconductors COA Certificate of Authenticity Microsoft Windows Product Key COM Communications Port Term for the serial interface CP Communication Processor Communication computer CPU Central Processing Unit CPU CRT Cathode Ray Tube CSA Canadian ...

Страница 152: ...d to a local area LCD Liquid Crystal Display Liquid crystal display LED Light Emitting Diode Light emitting diode LPT Line Printer Printer port MAC Media access control Media access control MLFB Machine readable product designation MUI Multilanguage User Interface Multilanguage operating system with Windows with language toggling 5 languages German English French Spanish and Italian NC Not Connect...

Страница 153: ...disk error diagnostics program SNMP Simple Network Management Protocol Network protocol SSD Solid State Drive SW Software TxD Transmit Data Data transfer signal UL Underwriters Laboratories Inc US organization for tests and certifications ac cording to own or binational standards with CSA Canada standards USB Universal Serial Bus VCC Positive supply voltage of integrated circuits VDE Verein deutsc...

Страница 154: ...List of abbreviations D 1 Abbreviations SIMATIC IPC677E 154 Operating Instructions 04 2019 A5E45117996 AA ...

Страница 155: ...Open 72 Power off 57 switch on 55 Device fan See Fan Device fan supply 131 Dimension drawing 123 Dimension drawings Expansion card 124 Dimensions 123 Dimensions of the device 123 Drive drive in the removable tray 79 E EAC 128 Equipotential Bonding 47 Ethernet 118 Ethernet strain relief 54 EU Declaration of Conformity 125 Expansion Memory 76 Expansion modules Installing 74 F Fan 92 Removal 92 FCC 1...

Страница 156: ...m 62 Show faulty drive 62 Online ordering system 53 Open Device 72 Operating system Initial commissioning 55 P Package contents 35 Checking 35 Packaging 35 Checking 35 Removing 35 Partitioning 119 PCI hardware interrupt 141 Power consumption 111 Power factor correction 114 Power requirements 113 Power supply AC voltage supply 114 DC voltage supply 114 WinAC module 134 Power supply fan Removal 95 1...

Страница 157: ...eator SIMATIC IPC Remote Manager 68 SIMATIC S7 53 Slot cover 75 Strain relief Ethernet cable 54 Supply voltage 111 For countries other than the USA and Canada 46 USA and Canada 46 Switching on the device Configure automatic startup 55 System resources 136 I O address allocation 136 T Temperature 115 W Weight 111 WinAC module Power supply connection 134 ...

Страница 158: ...Index SIMATIC IPC677E 158 Operating Instructions 04 2019 A5E45117996 AA ...