Overview
1.2 Design of the built-in units
SIMATIC IPC477D, IPC477D PRO
26
Operating Instructions, 11/2016, A5E31347228-AF
1.2.7
Interfaces and operator controls for devices with 240 V AC power supply
The figures showing the interfaces apply to the following devices:
●
IPC477D with 15" display
●
IPC477D with 19" display
●
IPC477D with 22" display
Devices with PROFIBUS interface
①
On/Off switch
②
240 V AC power supply
③
Protective conductor connection
④
Slot for external CFast card
With cover
⑤
4 x USB port
USB 3.0 high speed/high current
⑥
Display port
⑦
DVI-I port
DVI connector for CRT or LCD monitor (VGA via
DVI-VGA adapter) with DVI interface
⑧
2 x Ethernet port
RJ45 Ethernet connection 1 for 10/100/1000 Mbps or
RJ45 Ethernet connection 2 for 10/100/1000 Mbps (not for
PROFINET device)
⑨
COM 1 port
Serial interface, 9-pin D-sub plug
⑩
COM 2 port
Serial interface, 9-pin D-sub plug
⑪
PROFIBUS DP/MPI interface
PROFIBUS DP/MPI interface RS 485, isolated,
9-pin D-sub socket