Technical specifications
7.4 Technical data
SIMATIC IPC227G
Operating Instructions, 06/2021, A5E50059933-AA
69
7.4.2
Ambient conditions
Climatic ambient conditions
For permitted mounting positions, see section Preparing for installation (Page 18).
Temperature
, tested in accordance with IEC 60068-2-1, IEC 60068-2-2 and IEC 60068-2-14
Operation, x6211E, without M.2 Module
0 °C to +55 °C applies to device for horizontal mount-
ing positions
Operation, x6413E/x6414RE, without M.2
Module;
or x6211E, M.2 Module load max. 2.5W
0 °C to +50 °C applies to device for horizontal mount-
ing positions
Operation, x6413E/x6414RE, without M.2
Module;
0 °C to +45 °C applies to device for vertical mounting
positions
Operation, x6413E/x6414RE, M.2 Module
load max. 2.5W;
or x6211E, M.2 Module load max. 5W
0 °C to +45 °C applies to device for horizontal mount-
ing positions
Operation, x6413E/x6414RE, M.2 Module
load max. 5W
0 °C to +40 °C applies to device for horizontal mount-
ing positions
Temperature during storage/transport
-20 °C to +70 °C
Gradient
•
Operation: Max. 10 °C/h
•
Storage: 20 °C/h, no condensation
Relative humidity
, tested in accordance with IEC 60068-2-78, IEC 60068-2-30
Operation
8% to 85% at 30 °C, no condensation
Gradient ≤ 10℃/h
Storage/transport
8% to 90% at 25/55 °C, no condensation
Gradient ≤ 20℃/h
Atmospheric pressure
Operation
1080 to 627 hPa, corresponds to an altitude of -1000
to 3000 m
Storage/transport
1080 to 660 hPa, corresponds to an altitude of -1000
to 3500 m
Multiplication factors for equipment ambient temperature of operation at altitudes up to
3000m
, tested in accordance with IEC 61131-2:2017
Altitude
Derating ratio for temperature
1
0 to 2000
2
1.0
3000
0.9
1
: Equipment ambient temperature rating at 2000 m.
2
: Atmospheric pressure and air density increases with decreasing altitude. Therefore utilization of
the derating factor for 0 m to 2000 m for altitudes below sea level is considered conservative.