Expanding and assigning parameters to the device
5.3 Installing and removing M.2 NVMe/ SATA SSD
SIMATIC IPC227G
44
Operating Instructions, 06/2021, A5E50059933-AA
Remove the COM interface and its jumpers on the moth-
erboard.
Follow above steps to install the M.2 Module with an ad-
ditional interface-card on the X100 or X101 interfaces
slot.
Note:
The cable length of the M.2 Module should not be
shorter than 100 mm and no longer than 200 mm.
Secure the additional interface-card in the position of the
COM interface with screws.
Procedure - Removing the M.2 Module
Follow the above steps in reverse order to remove the M.2 Module.
5.3
Installing and removing M.2 NVMe/ SATA SSD
The device has a slot for M.2 NVMe or SATA SSD on the side of the interface panel.
Requirement
•
The device is disconnected from the power supply.
•
A M.2 NVMe/SATA SSD that is approved for industrial applications.
•
A T10 screwdriver