Technical data
9
Because you insert the SIMATIC IOT2000 SG-Shield into the SIMATIC IOT2050, the same
technical specifications apply as for SIMATIC IOT2050:
• Type of protection: IP20 in accordance with IEC 60529;
• Electromagnetic compatibility;
• Ambient conditions
All technical specifications can be found in the SIMATIC IOT2050 Operating Instructions (
support.industry.siemens.com/cs/de/en/view/109779016
) in the section "Technical
specifications".
Rated conditions
Ambient temperature
0 ... 55 °C
Load cell interface
Accuracy
0.05%
Input signal resolution
± 1 000 000
Measuring range
± 4 mV/V
Supply of the full bridge
4.85 V DC +2/-3%
Connection
4-wire or 6-wire
Strain gauge input resistance
50 … 4100 Ω
Electrical isolation
500 V AC
SIMATIC IOT2000 SG-Shield
Operating Instructions, 08/2021, A5E50985404-AA
29