Operation via the CB Gate user interface
8.2 Menu items
SIMATIC Ident CB Gate
48
Operating Instructions, 08/2022, C79000-G8976-C671-01
8.2.3
"Black list" menu item
The "Black list" menu item is divided into the following areas:
•
Settings
•
Black listed transponders in PLC
Figure 8-4
"Black list" menu item
Settings
You can enable or disable the Black list filter algorithm in the "Settings" area. Note that the
algorithm can only be enabled/disabled when the CB Gate is disabled ("Home > Enable
Tiregate > Off").
Table 8- 6
Description of the "Settings" parameters
Parameter
Description
Disable Black list
If the function is enabled, transponders that have already been processed are
hidden in a targeted manner.
Note: The "Black List" is enabled in the delivery state. This ensures that
transponders are not read multiple times in succession. A transponder is only
detected again if at least five other transponders have been read between
the first and the following read operation.
The recommendation is to disable the Black list for test purposes only.
Black listed transponders in PLC
The five transponders currently in the Black list are shown in the "Black listed transponders in
PLC" area. They are filtered out in the next read operations.
You can delete all entries from the list with the "Delete" button.
Содержание SIMATIC Ident CB Gate
Страница 20: ...Description SIMATIC Ident CB Gate 20 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 62: ...Alarm error and system messages SIMATIC Ident CB Gate 62 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 64: ...Maintenance and service SIMATIC Ident CB Gate 64 Operating Instructions 08 2022 C79000 G8976 C671 01 ...
Страница 70: ...Service Support SIMATIC Ident CB Gate 70 Operating Instructions 08 2022 C79000 G8976 C671 01 ...