Handling the Mobile Panel
4.4 Testing Mobile Panel readiness for operation
TP1000F Mobile RO
70
Operating Instructions, 08/2017, A5E39831415-AA
4.4
Testing Mobile Panel readiness for operation
This section describes how to check the operational readiness of the Mobile Panel after you
have connected the connecting cable and, if necessary, a memory card to the Mobile Panel.
Requirement
●
A connection box compatible with the HMI device is in place and ready for operation.
See "Mobile Panel and connection box compatibility (Page 24)".
Procedure
Power on
1.
Plug the connecting cable into the connection box.
If the HMI device does not start, the wires at interface X10 in the connection box may
have been crossed. Check the connected wires and change the connections if
necessary.
When plugging and unplugging the connecting cable, follow "Mobile Panel and
connection box compatibility (Page 24)". The HMI device display lights up once the cable
is connected. A start screen is displayed during startup. The desktop with the Start
Center is then displayed, see section "Desktop and Start Center (Page 73)".
2.
The "Safety operation" dialog appears.
The dialog is displayed if the connection box has not been configured. The dialog does
not open if the HMI device is connected to a configured connection box.
You can find additional information in the section "Assigning a safety-related operating