6-6
OP37/Pro Equipment Manual
Release 7/98
6.3
Replacing the Floppy Disk Drive
The floppy disk drive is secured to a mounting plate at the rear of the OP. The
screws for mounting the floppy disk drive on the mounting plate are located
behind the outer rear panel.
To replace the floppy disk drive, proceed as follows:
1. Detach the ribbon cable.
2. Remove the outer rear panel.
3. Undo the floppy disk drive attaching screws.
4. Change the floppy disk drive and secure it to the bracket.
5. Attach the ribbon cable and affix the outer rear panel.
To detach the ribbon cable, proceed as follows:
1. Slide the connector cover
1
in the direction of the arrow as shown in
Figure 6-5.
2. Disconnect ribbon cable
2
.
When connecting the cable to the terminal on the new floppy disk drive,
make sure that the side of the cable with the end colored blue is facing up-
wards and the cable contacts are facing downwards.
1
2
Blue cable
termination
Floppy disk drive
Figure 6-5
Open clamp lock and detach ribbon cable connector