![Siemens SIMATIC FS600 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/siemens/simatic-fs600/simatic-fs600_instruction-manual_383286034.webp)
34
5.3.4
Range of the measurement field
The maximum distance for contour measurement at a reflectance factor of 80% (white
gipsum) is 50 m.
a = Detection zone
b = Measurement field
Fig. 5.3-2:
Detection of objects depending on the reflectance factor. The reference
point of the distance measurement is the axis of the rotating mirror.
5.3.5
Required Detection Zone Additions Z
The SIMATIC FS600 Laser Scanner is equipped with a selectable dust algorithm to
ensure optimum freedom from interference.
The following detection zone additions must be taken into account:
Activation and deactivation of the function is performed by SIMATIC FS600
Parameterization Software LS4soft.
Addition Z
SM
if dust
suppression is deactivated
83 mm
Addition Z
SM
if dust
suppression
is activated
83 mm (for a detection zone size < 3.5 m)
100 mm (for a detection zone size > 3.5 m)
Remission in %
Reflectors
White gypsum
Writing paper
Gray carton
Black corduroy
Distance in m
a
b
15
Содержание SIMATIC FS600
Страница 2: ...600672 ...
Страница 109: ...109 ...