MPI/DP
Pinout of the MPI/DP socket:
1
5
6
9
Pin No.
Designation
Description
Input/Output
1
-
Unassigned
-
2
-
Unassigned
-
3
LTG_B
Signal line B of MPI module
Input/output
4
RTS_AS
RTSAS, control signal for received data
stream. The signal is “1” active when the
directly connected programmable controller is
sending.
Input
5
M5EXT
M5EXT return line (GND) of the 5 V power
supply. The current load caused by an
external user connected between P5EXT and
M5EXT must not exceed the maximum of
90 mA.
Output
6
P5 EXT
P5EXT power supply (+5 V) of the 5 V power
supply. The current load caused by an
external user connected between P5EXT and
M5EXT must not exceed the maximum of
90 mA.
Output
7
-
Unassigned
-
8
LTG_A
Signal line A of the MPI module
Input/output
9
RTS_PG
RTS output signal of the MPI module. The
control signal is “1” when the programming
device is sending.
Output