Technical specifications
9.3 Technical specifications
SIMATIC Field PG M6
78
Operating Instructions, 12/2018, A5E43198909-AA
Electromagnetic compatibility (EMC)
Emitted interference
EN 61000-6-3, EN 61000-3-2 Class D and EN 61000-3-3
Noise immunity:
Mains borne disturbance variables on
supply lines
± 2 kV; (according to IEC 61000-4-4; Burst)
± 1 kV; (according to IEC 61000-4-5; Surge sym./
line to line)
± 2 kV; (according to IEC 61000-4-5; Surge sym./
line to earth)
Noise immunity on signal lines
•
± 1 kV;
(to IEC 61000-4-4; burst; length < 30 m)
•
± 2 kV;
(to IEC 61000-4-4; burst; length > 30 m)
•
± 2 kV;
(acc. to IEC 61000-4-5; surge pulse/cable to ground;
length > 30 m)
Immunity to discharges of static electricity ± 4 kV, contact discharge (according to IEC 61000–4–2;
ESD)
± 8 kV, air discharge (according to IEC 61000-4-2; ESD)
Immunity to RF interference
10 V with 80% amplitude modulation with 1 kHz,
from 150 kHz to 80 MHz (according to IEC 61000-4-6)
10 V/m with 80 % amplitude modulation with 1kHz,
80 MHz to 1000 MHz
(according to IEC 61000-4-3)
3 V/m with 80% amplitude modulation with 1 kHz,
1.4 GHz to 6 GHz (according to IEC 61000-4-3)
Magnetic field
30 A/m, 50 Hz and 60 Hz (according to IEC 61000-4-8)
Climatic conditions
Temperature
tested to IEC 60068-2-1, IEC 60068-2-2
During operation
+ 5 °C to + 40 °C max. 10 °C/h (no condensation)
Storage/transport
-20 °C to + 60 °C at max. 20 °C/h (no condensation)
Relative humidity
tested to IEC 60068-2-78, IEC 60068-2-30,
IEC 60068-2-14
During operation
5% to 85% at 30° C (no condensation)
Storage/transport
5% to 95% at 25° C (no condensation)