Wiring and Fitting
5-12
ET 200S Distributed I/O System
EWA-4NEB 780602402-12
Releasing the wiring of the terminal module with Fast Connect
1. Insert the screwdriver into the opening below the locking mechanism
until it
stops
.
2. Use the screwdriver to lever and push the locking mechanism upwards.
3. The wiring is disconnected: remove the wire.
1
3
4
2
Figure 5-5
Releasing the wiring of the terminal module with Fast Connect
Removing any remains of the conductor (only if necessary)
To remove any remains of the conductor (insulation), you can deinstall the locking
mechanism from the terminal module (see Step 3). To do this, the locking
mechanism must be open (upper position). You can only insert the locking
mechanism in the upper position (see Step 4).
1. Insert the screwdriver in the opening below the locking mechanism (the tip of
the screwdriver is on the lip of the locking mechanism).
2. Press the screwdriver downwards to lever the locking mechanism out of the
terminal module.
3. Remove the locking mechanism from the terminal module. Remove any
remains of the conductor from the locking mechanism.
4. Use your fingers to press the locking mechanism back into the opening.
Important: Make sure the locking mechanism is inserted in the correct position,
otherwise you can damage the clamping unit.
4
2
1
Note the position of th
mechanism
3
Figure 5-6
Removing the locking mechanism from the terminal module
Содержание SIMATIC ET 200S
Страница 42: ...Product Overview 1 16 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 64: ...Brief Instructions on Commissioning ET 200S 2 22 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 112: ...Configuration Options 3 48 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 232: ...Commissioning and Diagnostics 6 72 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 244: ...General Technical Specifications 7 12 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 274: ...Interface Modules 8 30 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 538: ...4 IQ SENSE 13 18 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 564: ...Address Space of the Input and Outputs of the ET 200S C 4 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 574: ...Response Times D 10 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 580: ...Special Measures for Interference Free Operation F 4 ET 200S Distributed I O System EWA 4NEB 780602402 12 ...
Страница 600: ...Product Information on the Use of subassemblies modules in a Zone 2 Hazardous Area 2 A5E00352937 02 ...