Possible start modes
Start mode
Meaning
Operator
You can start the released Batch with the menu command Control > Start .
Immediate
When released, the batch is started as soon as the units required at the start of
the control recipe are free.
Time-driven
The batch is started on a particular day, at a particular time. The start time and
date must be specified.
Note
Batches with the start mode "Immediate" are started before batches with the start mode "Time-
driven" (start mode "Immediate" takes priority) if the same units are involved.
9.6.2.8
Displaying unit allocation and changing it if necessary
Unit allocation and run time
A unit can only be involved in the production of one batch at any one time. The unit allocation
is displayed along with the duration of the allocation and is not related to any particular recipe.
The length of time required by units involved in a batch is set when the recipe is created. The
times are relative to the start of the batch and take into account the actual quantity of the batch.
If necessary, you can adapt the unit allocation in the properties dialog of the batch.
Note
The allocation times of the units are planning values used to optimize the use of facilities.
Please remember that these allocation times are not exactly the same as the actual times
required for batch control.
Procedure in the BatchCC:
1. In the "Orders" folder in the BatchCC select the object "Batch" below the production order.
2. Select the menu item Edit > Properties.
Result: The dialog "Properties of <batch name>" is displayed.
3. Select the "Allocation" tab.
Result: The units reserved for the recipes are displayed in the table.
4. If required, modify the unit allocation. The "Unit" list box shows only the units that also have
the recipe phases being used.
5. Confirm your changes with "OK".
Overview of the unit allocations
You can also open an overview (read only) of the unit allocations with the menu command
Planning > Unit allocation.
BATCH Control Center
9.6 Batch Planning
SIMATIC BATCH V8.2
358
Operating Manual, 02/2016, A5E35958174-AA
Содержание SIMATIC BATCH
Страница 30: ...Security information SIMATIC BATCH V8 2 30 Operating Manual 02 2016 A5E35958174 AA ...
Страница 135: ...Example Engineering 7 1 Basic engineering for PCS 7 SIMATIC BATCH V8 2 Operating Manual 02 2016 A5E35958174 AA 135 ...
Страница 403: ...BATCH Control Center 9 8 Batch control SIMATIC BATCH V8 2 Operating Manual 02 2016 A5E35958174 AA 403 ...
Страница 584: ...BATCH Recipe Editor 10 5 Other functions SIMATIC BATCH V8 2 584 Operating Manual 02 2016 A5E35958174 AA ...
Страница 722: ...Appendix 13 4 Command line parameters for BatchCC SIMATIC BATCH V8 2 722 Operating Manual 02 2016 A5E35958174 AA ...
Страница 1158: ...Index SIMATIC BATCH V8 2 1158 Operating Manual 02 2016 A5E35958174 AA ...