CPU module
3-12
Hardware - SIMADYN D
Edition 03.2001
The program is loaded in a program memory module
•
MS5
2 Mbyte Flash-EPROM, 8 Kbyte EEPROM
•
MS51
4 Mbyte Flash-EPROM, 8 Kbyte EEPROM
•
MS52
8 MByte Flash-EPROM, 8 KByte EEPROM
An RS 232 interface (V.24) with service protocol DUST 1
with 19.2 kbaud
is
permanently installed in
connector X01
(9-pin sub-D socket). It is used to:
•
test and commission the user program (using CFC or "basic IBS")
•
loading the user program from the PC (only in this module)
8 binary inputs can be connected at the 10-pin
connector X5
.
The screw terminals for the binary inputs are available via the interface
modules (can be connected using cable SC7):
Interface module
Function
SB10, SU10
Electrical 1:1 connection
SB60, SB61
With electrical isolation (floating) and signal conversion
Table 3-7 Possible interface modules for PM6
MS5, MS51, MS52
Serial service
interface
Binary inputs
Interface modules