Power supply
8.2 SIDOOR NT40
ATE500E
110
System Manual, 09/2017, A5E33917696-AD
Output line X2
X2 is the output line connecting to the SIDOOR controller.
Connections
UA+, UA-, FE
Cable type
H05RN-F 3G1
Cable length
1.5 m
Connector(s)
WAGO 721-103/026-045
Short-circuit protection
Output X2 is short-circuit proof.
WARNING
Dangerous electrical voltage
May cause death, serious injury or material damage.
The third line brought out at the output is a functional grounding connection. The functional
grounding connection must not be understood or used as grounding in the sense of a PE
connection!