Power supply
8.1 SIDOOR NT40
AT40, ATD400V, ATD400K, ATD4xxW, ATD400S, ATE250S, ATD400T
System Manual, 06/2016, A2B00096162-AN
263
8.1.3
Connecting terminals
Input line X1
X1 is the connection line to the power supply.
Connections
L, N, PE 195 - 265 VAC
Cable type
H05RN-F 3G1
Cable length
2 m
Connector(s)
Extruded protective Schuko-type socket,
10 / 16 A, 250 V AC, double-protected connecting
cable according to DIN 49.441, CEE7 / VII.
Output line X2
X2 is the output line connecting to the SIDOOR controller.
Connections
UA+, UA-, FE
Cable type
H05RN-F 3G1
Cable length
1.5 m
Connector(s)
WAGO 721-103/026-045
The rated data of the output are:
Rated output voltage
36 V
Rated output current
2.5 A
Continuous output power rating
<100 W
WARNING
Dangerous electrical voltage.
May cause death, serious injury or property damage.
The third line brought out at the output is only a functional grounding connection, this must
not be regarded or used as a ground in the sense of a PE connection!