Description
2.2 Possible uses and portfolio
Air circuit breaker 3WL10
16
Manual, 11/2017, L1V30499596002-01
2.2
Possible uses and portfolio
Possible uses
The 3WL10 circuit breaker performs the different protection tasks and can be used in the
following areas:
Field of
application
Building
Industry
Breaking capacity 42 to 66 kA
Segments
Commercial
buildings
Infrastructure
Industrial
buildings
Functional
enclosure
Production/
process
automation
Examples
Office buildings,
banks,
hotels, cinemas,
shopping malls,
hospitals,
universities,
schools
Airports,
train stations,
sports stadiums,
ports,
exhibition sites
Industrial parks,
warehouses,
logistics centers
Paper industry,
computer centers,
oil & gas industry,
foodstuffs
industry
Presses,
galvanizing lines,
rolling mills,
grinding mills,
agitators and
mixers,
production lines
The 3WL10 air circuit breaker is used for the following functions:
●
Line protection
●
Standard applications up to 66 kA
●
Generator protection
●
High breaking capacity
●
Selectivity, in particular, for high requirements regarding time-selective coordination
●
Communication
●
As a version of a non-automatic air circuit breaker in accordance with IEC 60947-3
For this purpose, the focus is on the following applications of the circuit breaker:
●
Main distribution board
●
Industrial distribution systems
Содержание SENTRON 3WL10
Страница 1: ......
Страница 2: ......
Страница 8: ...Table of contents Air circuit breaker 3WL10 6 Manual 11 2017 L1V30499596002 01 ...
Страница 14: ...Introduction 1 3 Safety instructions Air circuit breaker 3WL10 12 Manual 11 2017 L1V30499596002 01 ...
Страница 21: ...Description 2 2 Possible uses and portfolio Air circuit breaker 3WL10 Manual 11 2017 L1V30499596002 01 19 ...
Страница 108: ...Accessories 3 5 Breaker Data Adapters and test devices Air circuit breaker 3WL10 106 Manual 11 2017 L1V30499596002 01 ...
Страница 128: ...Application planning 4 3 Communication planning Air circuit breaker 3WL10 126 Manual 11 2017 L1V30499596002 01 ...
Страница 152: ...Connection and commissioning 5 4 Commissioning Air circuit breaker 3WL10 150 Manual 11 2017 L1V30499596002 01 ...
Страница 170: ...Operation 6 3 Troubleshooting Air circuit breaker 3WL10 168 Manual 11 2017 L1V30499596002 01 ...
Страница 180: ...Technical specifications Air circuit breaker 3WL10 178 Manual 11 2017 L1V30499596002 01 ...
Страница 198: ...Dimension drawings 9 2 Withdrawable breaker Air circuit breaker 3WL10 196 Manual 11 2017 L1V30499596002 01 ...
Страница 199: ...Air circuit breaker 3WL10 Manual 11 2017 L1V30499596002 01 197 Circuit diagrams 10 ...
Страница 212: ...Circuit diagrams Air circuit breaker 3WL10 210 Manual 11 2017 L1V30499596002 01 ...
Страница 230: ...List of abbreviations C 1 Table of abbreviations Air circuit breaker 3WL10 228 Manual 11 2017 L1V30499596002 01 ...
Страница 233: ......
Страница 234: ......