6.7.2
Connecting devices with 100 to 240 V AC power supply
Safety note on devices with 100 to 240 V AC power supply
WARNING
Danger from line voltage
The supply voltage for the devices listed is 100 to 240 V AC.
This device can only function correctly and safely if it is transported, stored, set up, and
installed correctly, and operated and maintained as recommended.
Connecting and disconnecting may only be performed by an electrical specialist.
Connect or disconnect power supply cables only when the power is turned off.
WARNING
Devices with a 100 to 240 V AC power supply do not have an ATEX or IECEx approval.
Devices with a 100 to 240 V AC power supply are not approved for use in hazardous areas
according to 2014/34/EU ATEX or IECEx.
NOTICE
Securing cables with dangerous voltage
Make sure that the connector cannot be released accidentally by pulling on the connecting
cable. Lay the cables in cable ducts or cable channels and secure the cables, where
necessary, with cable ties.
6.7.2.1
Overview
Table 6-5
100 to 240 V AC voltage
Device
Device version (power supply)
100 to 240 V voltage
Redundant
Single
XR324-4M EEC
1 x 100 to 240 V AC / 60 to 250 V DC
-
●
2 x 100 to 240 V AC / 60 to 250 V DC
●
-
Connecting
6.7 Power supply
SCALANCE XR-300M EEC
54
Compact Operating Instructions, 11/2019, A5E02661176-14
Содержание SCALANCE XR324-4M EEC
Страница 10: ...Introduction SCALANCE XR 300M EEC 10 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Страница 12: ...Safety notes SCALANCE XR 300M EEC 12 Compact Operating Instructions 11 2019 A5E02661176 14 ...
Страница 84: ...Index SCALANCE XR 300M EEC 84 Compact Operating Instructions 11 2019 A5E02661176 14 ...