SCALANCE XR-500
Operating Instructions, 05/2017, A5E03275845-11
55
Connecting
5
5.1
Commissioning
WARNING
Commissioning devices and replacement devices
If you use redundancy mechanisms (HRP/MRP ring redundancy and/or redundant coupling
of rings with standby), open the redundant path before you insert a new or replacement
device in an operational network. A bad configuration or attachment of the Ethernet cables
to incorrectly configured ports causes overload in the network and a breakdown in
communication.
A device may only be inserted in a network and connected in the following situations:
•
With HRP/MRP:
–
Ring redundancy must be activated
–
The mode must be selected correctly.
–
The ring ports of the device being inserted in the HRP/MRP ring must be configured
as ring ports.
•
With standby link:
–
The standby connection must be activated.
–
The "Standby Connection Name" must match the name of the partner device.
–
The port must be configured as a standby port.
For further information, refer to the configuration manuals (Page 5).
Содержание SCALANCE XR-500
Страница 16: ...Safety notes 2 1 Security recommendations SCALANCE XR 500 16 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 36: ...Description of the device 3 5 Combo ports SCALANCE XR 500 36 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 72: ...Connecting 5 8 Functional ground SCALANCE XR 500 72 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 74: ...Uninstalling SCALANCE XR 500 74 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 94: ...Technical data 8 5 Switching properties SCALANCE XR 500 94 Operating Instructions 05 2017 A5E03275845 11 ...
Страница 110: ...Certification 10 2 Mechanical stability in operation SCALANCE XR 500 110 Operating Instructions 05 2017 A5E03275845 11 ...