If changes are made to the configuration, the device stores the configuration directly on the C-
PLUG, if this is in the "ACCEPTED" status and in internal memory.
Response to errors
Inserting a C-PLUG that does not contain the configuration of a compatible device type and
inadvertently removing the C-PLUG, or general malfunctions of the C-PLUG are indicated by the
diagnostic mechanisms of the device.
• Fault LED
• Web Based Management (WBM)
• SNMP
• Command Line Interface (CLI)
• PROFINET diagnostics
The user then has the choice of either removing the C-PLUG again or selecting the option to
reformat the C-PLUG.
4.6.2
Replacing the C-PLUG
Position of the C-PLUG
NOTICE
Loss of water and dust protection
If the cover is not mounted correctly, the device is not water and dust proof.
NOTICE
Loss of the railway approval
If you use an unvarnished C-PLUG, the device does not comply with the railway standard
EN50155.
NOTICE
Do not remove or insert a C-PLUG during operation
The C-PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a C-PLUG is inserted at one second intervals. If it is detected
that the PLUG was inserted or removed, there is a restart.
The C-PLUG slot is on the top of the device housing under a cover.
Description of the device
4.6 C-PLUG
SCALANCE XP-200
38
Operating Instructions, 03/2021, C79000-G8976-C428-08
Содержание SCALANCE XP208EEC
Страница 10: ...Safety notices SCALANCE XP 200 10 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 16: ...Recommendations on network security SCALANCE XP 200 16 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 52: ...Installation 5 5 Rack mounting SCALANCE XP 200 52 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 70: ...Connecting up 6 7 Functional ground SCALANCE XP 200 70 Operating Instructions 03 2021 C79000 G8976 C428 08 ...
Страница 88: ...Dimension drawings SCALANCE XP 200 88 Operating Instructions 03 2021 C79000 G8976 C428 08 ...