Diagnostics
12.5 RMON
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
936
Configuration Manual, 06/2016, C79000-G8976-C252-11
Syntax
Call the command without parameter assignment:
rmon
Default: disabled
Result
The Remote Monitoring function is enabled.
Further notes
You disable this function with the
no rmon
command.
You can display the status of this function and other information with the
show rmon
command.
12.5.2.2
no rmon
Description
With this command, you disable the Remote Monitoring function.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
no rmon
Default: disabled
Result
The Remote Monitoring function is disabled.
Further notes
You enable this function with the
rmon
command.
You can display the status of this function and other information with the
show rmon
command.