Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
85
The parameter has the following meaning:
Parameter
Description
Range of values / note
longitude
Input box for the longitude coordinate
max. 32 characters
To use spaces in the entry, enter
the longitude coordinate in
quotes:
coordinates longitude
"123 456"
Result
The longitude coordinate is created.
3.1.12.6
ethernetip
Description
With this command, you set whether EtherNet/IP will be enabled or disabled after the next
device restart.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ethernetip {off|on}
The parameters have the following meaning:
Parameter Description
Range of values / note
off
EtherNet/IP will be disa-
bled after the next re-
start.
-
on
EtherNet/IP will be ena-
bled after the next re-
start.
•
When EtherNet/IP is turned on, PROFINET is turned off.
The switchover from EtherNet/IP and PROFINET has no
effect on DCP.
•
If a PROFINET connection is established; in other words
the PROFINET AR status is "Online", you cannot enable
EtherNet/IP.