Configuration
3.1 System
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
82
Configuration Manual, 06/2016, C79000-G8976-C252-11
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
cli-console-timeout [seconds(60-600)]
The parameters have the following meaning:
Parameter
Description
Range of values / note
seconds
Time in seconds until automatic logout
after the last entry
60 ... 600
Default: 300
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logout with the
no cli-console-timeout
command.
You display the current timeout setting with the
show cli-console-timeout
command.
3.1.12.2
no cli-console-timeout
Description
With this command, you disable the automatic logout.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no cli-console-timeout