Layer 3 functions
9.7 RIPng (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
700
Configuration Manual, 06/2016, C79000-G8976-C252-11
9.7.3.4
no distribute prefix
Description
This command disables the filtering of the routing information according to an IPv6 address
for incoming or outgoing routing information.
Note
This command is available only with layer 3.
Requirement
You are in the RIPng router configuration mode.
The command prompt is as follows:
cli(config-ripng)#
Syntax
Call up the command with the following parameters:
no distribute prefix <ip6_add> {in | out}
The parameters have the following meaning:
Parameter
Description
Values
ip6_add
IPv6 address
Enter a valid IPv6 address
in
The filtering for incoming routing information is
disabled.
-
out
The filtering for outgoing routing information is
disabled.
-
Result
Filtering is disabled.
Further notes
You enable filtering with the
distribute prefix
command.
You display the configured filters with the
show ipv6 rip filter
command.