Layer 3 functions
9.7 RIPng (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 06/2016, C79000-G8976-C252-11
697
Commands relating to other topics that can be called in the Global Configuration mode can
be found in the relevant sections.
●
If you exit the Router Configuration mode with the
exit
command, you return to the
Global Configuration mode.
●
If you exit the Router Configuration mode with the
end
command, you return to the
Privileged EXEC mode.
Requirement
●
The device supports the routing function
●
IPv6 and IPv6 routing is activated.
Note
These commands are available only with layer 3.
9.7.3.1
distance
Description
With this command, you specify the administrative distance for the RIP protocol. This value
is taken into account if routing information is learned from different routing protocols.
The lowest value for the administrative distance "1" means the highest reliability of the
routing information. Routing information from a system with the value "255" is so unreliable
that it is not learnt by the neighbor routers.
Requirement
You are in the RIPng router configuration mode.
The command prompt is as follows:
cli(config-ripng)#
Syntax
Call up the command with the following parameters:
distance dist<1-255> [route-map <name(20)>]