Network protocols
7.4 DHCPv6 client (IPv6)
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
338
Configuration Manual, 06/2016, C79000-G8976-C252-11
Parameter
Description
Range of values / note
key-id
Keyword for the ID of the password
-
value
ID of the password
Enter a valid ID.
0 ... 4294967295
Result
The HMAC-MD5 function is configured.
Further notes
You configure the interface as a router port with the
no switchport
command.
You enable the function DHCPv6 client with the
ipv6 address dhcp
command.
You display the setting with the
show ipv6 dhcp interface
command.
7.4.2.2
ipv6 dhcp client information refresh minimum
Description
With this command, you configure the interval after which the DHCP client refreshes the
configuration parameters.
Requirement
●
DHCPv6 Is activated.
●
IPv6 is activated
●
The interface is an IP interface.
●
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
ipv6 dhcp client information refresh minimum <seconds value(600-4294967295)>
The parameter has the following meaning:
Parameters
Description
Range of values / note
seconds value Length of the interval in seconds
600 ... 4294967295
Default: 4294967295 (24 hours)