Properties
Properties
Half/full duplex, MDI‑X pinning
Transmission speed
10 / 100 Mbps
Optical connectors
Optical connectors
Quantity
2
Connectors
The attachment to Industrial Ethernet uses SC connector tech‐
nology (Subscriber Connector).
Properties
Transmission mode
100Base-FX complying with IEEE 802.3
Transmission speed
100 Mbps (Fast Ethernet)
Transmission medium
Multimode fiber-optic cable
Light source
LED/Class1-LASER "Eye safe"
Wavelength
1300 nm
Cable length (max.) *
)
At 50 µm fiber core diameter
3 km
At 62.5 µm fiber core diameter
3 km
Transmitter output (optical)
Minimum
At 50 μm
-23.5 dBm
At 62.5 μm
-20 dBm
Maximum
-14 dBm
Receiver input
Sensitivity min.
-31 dBm
Input power max.
-8 dBm
*) Depending on the cable used, you can find additional information in the "Industrial Ethernet /
PROFINET Passive network components" System Manual, see also section "Introduction",
paragraph "Additional documentation".
7.2
Technical specifications of the SCALANCE XB108-2(ST)
The following technical specifications apply to the SCALANCE XB108-2(ST).
Technical specifications
Electrical data
Power supply
Rated voltage
24 V AC/VDC
Voltage range
19.2 to 28.8 V AC/VDC Safety Extra Low
Voltage (SELV)
Design
Terminal block, 3 terminals
Properties
Implemented redundantly
Technical specifications
7.2 Technical specifications of the SCALANCE XB108-2(ST)
SCALANCE XB-100
34
Operating Instructions, 02/2019, C79000-G8976-C473-03
Содержание SCALANCE XB-100 Series
Страница 8: ...Introduction SCALANCE XB 100 8 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 10: ...Safety notices SCALANCE XB 100 10 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 22: ...Installation 4 2 Mounting on DIN rails SCALANCE XB 100 22 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 32: ...Upkeep and maintenance SCALANCE XB 100 32 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 44: ...Dimension drawings SCALANCE XB 100 44 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 54: ...Index SCALANCE XB 100 54 Operating Instructions 02 2019 C79000 G8976 C473 03 ...