ST/BFOC connectors
The attachment to Industrial Ethernet uses ST/BFOC con‐
nector technology (Straight Tip/Bayonet Fiber Optic Connec‐
tor).
5.3
Wiring rules
When wiring use cables with the following AWG categories or cross sections.
Wiring rules for ...
Spring-loaded terminals
connectable cable cross sec‐
tions for flexible cables ...
without wire end ferrule
0.2 - 1.5 mm
2
AWG: 24 - 14
with wire end ferrule with plastic
ferrule**
0.25 - 0.75 mm
2
AWG: 24 - 14
with TWIN wire end ferrule without
plastic ferrule**
0.25 - 1.5 mm
2
AWG: 24 - 18
Stripped length of the cable
10 mm
Wire end ferrule according to DIN 46228 without plastic ferrule**
10 mm
* AWG: American Wire Gauge
** See note "Wire end ferrules"
Note
Wire end ferrules
Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp
cross sections.
Crimp shapes with wave-shaped profile are unsuitable.
Connecting up
5.3 Wiring rules
SCALANCE XB-100
Operating Instructions, 02/2019, C79000-G8976-C473-03
27
Содержание SCALANCE XB-100 Series
Страница 8: ...Introduction SCALANCE XB 100 8 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 10: ...Safety notices SCALANCE XB 100 10 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 22: ...Installation 4 2 Mounting on DIN rails SCALANCE XB 100 22 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 32: ...Upkeep and maintenance SCALANCE XB 100 32 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 44: ...Dimension drawings SCALANCE XB 100 44 Operating Instructions 02 2019 C79000 G8976 C473 03 ...
Страница 54: ...Index SCALANCE XB 100 54 Operating Instructions 02 2019 C79000 G8976 C473 03 ...