Installation
5.2 Installing a switch
SCALANCE X-300
110
Operating Instructions, 05/2016, A5E01113043-20
5.2.3
Wall mounting
Wall mounting
Note
Installation fittings
When mounting on a wall, use mounting fittings suitable for the type of wall. For example, to
secure to concrete:
•
4 wall plugs, 6 mm in diameter and 30 mm long
•
4 screws 3.5 mm in diameter and 40 mm long
The wall mounting must be capable of supporting at least four times the weight of the
IE Switch X-300.
1.
Mount the switch on the wall.
2.
Connect the grounding of the switch according to the description in the section
Connecting the grounding (Page 130).
3.
Connect the power supply to the appropriate terminal block.
4.
Connect the cable for the signaling contact to the appropriate terminal block.
5.
Insert the terminal blocks into the sockets on the IE Switch X-300.
CAUTION
Grounding of the X-300EEC
The device is grounded via the bolts in the floor of the housing.
On the X-300EEC with power supply 100...240 V AC, you must always connect protective
ground via the bolts on the bottom of the device housing.
Note
For precise dimensions, refer to the dimension drawings in section Graphics (Page 283).
Note
Wall mounting of a rack device
For wall mounting of a rack device (R), use suitable fittings such as a mounting bracket.
Wall mounting of the IE Switch X-300EEC
To mount the IE Switch X-300EEC on a wall, you require an additional securing bracket. You
will find the dimensions for a suitable securing bracket in section Graphics (Page 283).