Firmware update
8
8.1
Firmware update with functional firmware
8.1.1
Firmware update over HTTP/HTTPS
Web Based Management or Command Line Interface
For information on a firmware updates using HTTP/HTTPS, refer to the section "System
Save & Load menu item".
8.1.2
Firmware update over TFTP
Web Based Management or Command Line Interface
For information on a firmware updates using TFTP, refer to the section "System Save &
Load menu item".
8.1.3
Firmware updates over FTP
Access over the console
If an IE switch has an IP address and there is an Ethernet connection to a PC or PG, follow
the steps below to update the firmware:
1.
Open a console window and type in the command ftp followed by the IP address of the IE
switch.
Example:
ftp 192.168.20.54
2.
For the login and password enter the same values as you use for WBM and CLI.
3.
Enter the "put" command followed by the name of the firmware file.
Example:
put v100031.lad
4.
Once the file has been loaded, the IE switch closes the FTP connection and restarts.