Parameters
disable
Disables location-based service.
aeroscout
Enables Aeroscout location-based service.
ekahau
Enables Ekahau location-based service.
Usage
Use the
server-ip
command to specify the IP address of the AeroScout/Ekahau server, after you
enable the service.
Examples
The following example enables the Aeroscout location-based service:
WLC.siemens.com
# lbs
WLC.siemens.com
:lbs# service aeroscout
server-ip
Use the
server-ip
command to set the location-based server IP address. The
server-ip
command is
accessible from the lbs context of the CLI.
server-ip A.B.C.D
Parameters
A.B.C.D
Specifies the IP address of the location-based server.
Usage
This command is visible only if a location-based service has been enabled via the
service
command.
The default IP address is 0.0.0.0.
Examples
The following example sets the IP address of the AeroScout server to 192.168.3.100:
WLC.siemens.com
:lbs# service aeroscout
WLC.siemens.com
:lbs# server-ip 192.168.3.100
show
Use the
show
command to display information about the location-based service. The show command is
accessible from the lbs context of the CLI.
show