snmp community index <CommunityIndex> name <CommunityName>
security <SecurityName> [context <Name>][{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
CommunityIndex
Index of the community
max. 32 characters
name
Keyword for the name of the community -
CommunityName
Name of the community
max. 32 characters
security
Keyword for the security name
-
SecurityName
Security name
max. 32 characters
context
Keyword for the context name
-
Name
Context name
max. 32 characters
Storage type
Specifies whether the settings remain
following a restart.
● :
The settings are lost after a
restart
● :
The settings are retained after
a restart
If optional parameters are not specified when configuring a community, the default values
apply.
Note
Community string
For security reasons, do not use the standard values "public" or "private". Change the
community strings following the initial installation.
The recommended minimum length for community strings is 6 characters.
Result
The settings are configured.
Further notes
You delete the details of an SNMP community with the
no snmp community index
command.
You show the details of an SNMP community with the
show snmp community
command.
You show the status information of the SNMP communication with the
show snmp
command.
8.6.2.7
no snmp community index
Description
With this command, you delete the details of an SNMP community.
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface