CLI Commands
4.4 D
SCALANCE W1750D CLI
86
Function Manual, 03/2019, C79000-G8976-C452-04
no…
Parameter
Description
deny-inter-user-
bridging
Prevents the inter-user bridging.
no…
Removes the configuration.
Usage Guidelines
Use this command if you have security and traffic management policies defined for upstream
devices.
Example
The following command disables inter-user bridging:
(scalance)(config)# deny-inter-user-bridging
(scalance)(config)# end
(scalance)# commit apply
Command Information
AP Platform
Command Mode
All platforms
Configuration mode
4.4.3
deny-local-routing
Description
This command disables routing traffic between two clients of an AP on different VLANs.
Routing traffic between the clients will be sent to the upstream device to make the forwarding
decision.
Syntax
deny-local-routing
no…
Parameter
Description
deny-local-routing
Disables local routing of traffic.
no…
Removes the configuration.