4.4
Installing on the DIN rail
Installation
1. Place the third housing guide of the device on the top edge of the DIN rail
①
.
2. Press the device down against the DIN rail until the spring catch locks in place
②
.
3. Connect the power supply, refer to the section "Power supply (Page 32)".
4. Connect the device to the local network, refer to the section "Properties and functions
(Page 11)".
5. Connect the terminal via as short a cable as possible ≤ 150 mm and a large cross-sectional
area of 1.5 mm² to the functional ground of the system, see section "Grounding (Page 33)
“.
6. Also connect the DIN rails of a system with functional ground.
Dismantling
1. Disconnect all connected cables.
2. Using a screwdriver, pull down the catch on the rear of the device.
3. Pull lower part of the device away from the DIN rail.
Installation and disassembly
4.4 Installing on the DIN rail