Certification
6.2 EMC and Environmental Type Tests
•
EN50121-4
Railway applications – Electromagnetic Compatibility – Emission and Immunity
of the Signaling and Telecommunications Apparatus
•
EN50121-3-2
Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus
•
EN 50155
Railway applications – Rolling stock – Electronic equipment
6.2
EMC and Environmental Type Tests
The RUGGEDCOM RSG909R has passed the following Electromagnetic Compatibility
(EMC) and environmental tests.
EMC Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclosure
Ports
20 V/m
Signal Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
DC Power
Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
AC Power
Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 4 kV @ 2.5 kHz, 5 kHz
4
Signal Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
DC Power
Ports
± 2 kV Line-to-Ground
± 1 kV Line-to-Line
3
IEC
61000-4-5
Surge
AC Power
Ports
± 4 kV Line-to-Ground
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Power
Ports
10 V
3
AC Power
Ports
10 V
3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
IEC
61000-4-8
Magnetic Field
Enclosure
Ports
100 A/m Continuous
1000 A/m for 1 s
42
RUGGEDCOM RSG909R