Installing the Device
2.5.2 Connecting External PoE Power
7. Using a #6 ring lug and #6-32 screw, secure the ground terminal on the power
source to the chassis ground connection on the device. Make sure the lug is
tightened to 1.7 N·m (15 lbf·in).
2
1
3
1
Stainless Steel Stud
2
#6-32 Screw
3
#6 Ring Lug
Figure 2.6
Chassis Ground Connection
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the
device is powered.
8. Install the terminal block cover.
2.5.2
Connecting External PoE Power
The RUGGEDCOM RSG2300P supports up to four 10/100Base-TX Power-over-Ethernet
(POE) Ports that require power from an external source.
Note
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with
power cabling no longer than 3 m (118 in).
Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode
AC power supply. For more information about this power supply, refer to
support.industry.siemens.com/cs/ww/en/view/109478699
.
16
RUGGEDCOM RSG2300P
Installation Manual, 04/2022, C79000-G8976-1047-18