Chapter 5
Technical Specifications
RUGGEDCOM RSG2100PF
Installation Guide
32
Operating Environment
10FL Ethernet Optical Specifications
Tx (dBm)
Mode
Connector
Type
Cable
Type (µm)
Tx λ (nm)
k
Minimum
Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
l
Power
Budget
(dB)
MM
ST
62.5/125
850
-16
-9
-34
-11.2
2
18
MM
ST
50/125
850
-19.8
-12.8
-34
-11.2
2
14.2
k
Typical.
l
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens
sales associates when determining maximum distances.
Fast Ethernet (10/100 Mbps) Optical Specifications
Tx (dBm)
Mode
Connector
Type
Cable
Type (µm) Tx λ (nm)
m
Minimum
Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
n
Power
Budget
(dB)
MM
ST
62.5/125
1300
-19
-14
-31
-14
2
12
MM
ST
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
SC
62.5/125
1300
-19
-14
-31
-14
2
12
MM
SC
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
MTRJ
62.5/125
1300
-19
-14
-31
-14
2
12
MM
MTRJ
50/125
1300
-22.5
-14
-31
-14
2
8.5
MM
LC
62.5/125
1300
-19
-14
-32
-14
2
13
SM
ST
9/125
1310
-15
-8
-32
-3
20
17
SM
SC
9/125
1310
-15
-8
-31
-7
20
16
SM
LC
9/125
1310
-15
-8
-34
-7
20
19
SM
SC
9/125
1310
-5
0
-34
-3
50
29
SM
LC
9/125
1310
-5
0
-35
3
50
30
SM
SC
9/125
1310
0
5
-37
0
90
37
SM
LC
9/125
1310
0
5
-37
0
90
37
m
Typical.
n
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens
sales associates when determining maximum distances.
Section 5.7
Operating Environment
The RUGGEDCOM RSG2100PF is rated to operate under the following environmental conditions.
Ambient Operating
Temperature
o
-40 to 85°C (-40 to 185 °F)
Ambient Storage Temperature
-40 to 85°C (-40 to 185 °F)