Chapter 4
Technical Specifications
RUGGEDCOM RSG2100
Installation Guide
30
Failsafe Relay Specifications
Non-Hazardous Environments
Input Range
Power Supply Type
Minimum
Maximum
Internal Fuse Rating
e
f
Maximum Power
Consumption
g
24 VDC
10 VDC
36 VDC
6.3 A(F)
48 VDC
36 VDC
72 VDC
3.15 A(T)
HI (125/250 VDC)
h
88 VDC
300 VDC
2 A(T)
HI (110/230 VAC)
h
85 VAC
264 VAC
2 A(T)
28 W
e
(F) denotes fast-acting fuse
f
(T) denotes time-delay fuse.
g
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
h
The HI power supply is the same power supply for both AC and DC.
Section 4.2
Failsafe Relay Specifications
Parameter
Value (Resistive Load)
Max Switching Voltage
240 VAC, 125 VDC
Rated Switching Current
2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
Maximum Switching Capacity
150 W, 500 VA
Section 4.3
Supported Networking Standards
Standard
10 Mbps Ports
100 Mbps Ports
1000 Mbps Ports
Description
IEEE 802.3
ü
10BaseT/10BaseFL
IEEE 802.3u
ü
100BaseTX/100BaseFX
IEEE 802.3x
ü
ü
ü
Flow Control
IEEE 802.3z
ü
1000BaseLX
IEEE 802.3ab
ü
1000BaseTx
IEEE 802.3ad
ü
Link Aggregation
IEEE 802.1D
ü
ü
ü
MAC Bridges
IEEE 802.1D
ü
ü
ü
Spanning Tree Protocol (STP)
IEEE 802.1p
ü
ü
ü
Class of Service (CoS)
IEEE 802.1Q
ü
ü
ü
VLAN (Virtual LAN) Tagging
IEEE 802.1w
ü
ü
ü
Rapid Spanning Tree Protocol (RSTP)
Содержание RUGGEDCOM RSG2100
Страница 4: ...RUGGEDCOM RSG2100 Installation Guide iv ...
Страница 12: ...Chapter 1 Introduction RUGGEDCOM RSG2100 Installation Guide 4 Description ...
Страница 28: ...Chapter 2 Installing Device RUGGEDCOM RSG2100 Installation Guide 20 Configuring the Device ...
Страница 36: ...Chapter 3 Communication Ports RUGGEDCOM RSG2100 Installation Guide 28 Removing a GBIC Optical Port ...
Страница 46: ...Chapter 5 Dimension Drawings RUGGEDCOM RSG2100 Installation Guide 38 ...
Страница 54: ...Chapter 6 Certification RUGGEDCOM RSG2100 Installation Guide 46 EMC and Environmental Type Tests ...