background image

Chapter 2

Installing the Device

RUGGEDCOM RS969

Installation Guide

14

Power Supply Wiring

Terminal #

Description

Usage

4

PS2 Neutral/-

PS2 Neutral/-

 is connected to the negative (-) terminal if the power source is DC or to the

(Neutral) terminal if the power source is AC.

5

PS2 Live/+

PS2 Live/+

 is connected to the positive (+) terminal if the power source is DC or to the (Live)

terminal if the power source is AC.

Section 2.5.2

Power Supply Wiring

The following illustrates how to connect the RUGGEDCOM RS969 to a single or dual power supplies.

NOTE

• For 100-240 VAC rated equipment, a 250 VAC appropriately rated circuit breaker must be installed.
• For 88-300VDC rated equipment, a 300VDC appropriately rated circuit breaker must be installed.
• A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
• For dual power supplies, separate circuit breakers must be installed and separately identified.
• When equipped with two HI voltage power supplies, independent AC sources can be used to power

the product for greater redundancy.

Single HI AC Power Supply Wiring

4

1

2

3

5

2

1

3

7

4

6

Figure 8: AC Power Supply Wiring Example (Mini Power Connector)

1.

 Mini Power Connector   

 

2.

 Neutral   

 

3.

 Line   

 

4.

 Safety Earth   

 

5.

 Safety   

 

6.

 250 VAC Breaker   

 

7.

 110/230 VAC Power Source

Содержание RUGGEDCOM RS969

Страница 1: ...RUGGEDCOM RS969 Installation Guide 07 2018 RC1038 EN 05 Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Accessories 6 Certification 7 ...

Страница 2: ...t and or networks They are important components in a holistic industrial security concept With this in mind Siemens products and solutions undergo continuous development Siemens recommends strongly that you regularly check for product updates For the secure operation of Siemens products and solutions it is necessary to take suitable preventive action e g cell protection concept and integrate each ...

Страница 3: ...Siemens Address Siemens Canada Ltd Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E mail ruggedcom info i ia siemens com Web https www siemens com ruggedcom ...

Страница 4: ...RUGGEDCOM RS969 Installation Guide iv ...

Страница 5: ...ber Optic Cables 6 1 5 Ingress Protection 6 1 6 Decommissioning and Disposal 7 Chapter 2 Installing the Device 9 2 1 General Procedure 9 2 2 Unpacking the Device 10 2 3 Mounting the Device 10 2 4 Connecting the Failsafe Alarm Relay 11 2 5 Connecting Power 12 2 5 1 Power Supply Connector Pin Out 12 2 5 2 Power Supply Wiring 14 2 5 3 Disabling Line to Ground Transient Protection 17 Chapter 3 Device ...

Страница 6: ... 26 5 5 Operating Environment 27 5 6 Mechanical Specifications 27 5 7 Dimension Drawings 27 Chapter 6 Accessories 31 6 1 Power 1 unit 31 6 2 Console 1 unit 32 6 3 Failsafe 1 unit 33 6 4 Ethernet 8 unit 34 6 5 LC Fiber Optic 2 unit 37 Chapter 7 Certification 39 7 1 Approvals 39 7 1 1 CSA 39 7 1 2 European Commission EC 40 7 1 3 FCC 40 7 1 4 FDA CDRH 40 7 1 5 ISED 41 7 1 6 ACMA 41 7 1 7 RoHS 41 7 1 ...

Страница 7: ...sing Documentation Training Customer Support Alerts The following types of alerts are used when necessary to highlight important information DANGER DANGER alerts describe imminently hazardous situations that if not avoided will result in death or serious injury WARNING WARNING alerts describe hazardous situations that if not avoided may result in serious injury and or equipment damage CAUTION CAUT...

Страница 8: ...ique mix of IT Telecommunications expertise combined with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com ruggedcom or contact a Siemens Sales representative Customer Support Customer support is available 24...

Страница 9: ... Installation Guide Preface Customer Support ix Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community ...

Страница 10: ...Preface RUGGEDCOM RS969 Installation Guide x Customer Support ...

Страница 11: ...lows the RUGGEDCOM RS969 to be placed in virtually any location The embedded RUGGEDCOM Rugged Operating System ROS provides advanced networking features such as Enhanced Rapid Spanning Tree eRSTP Port Rate Limiting and a full array of intelligent functionality for high network availability and manageability CONTENTS Section 1 1 Feature Highlights Section 1 2 Description Section 1 3 Required Tools ...

Страница 12: ...C Popular low voltage DC ranges 12 24 48 VDC Dual redundant parallel load sharing power supplies option Can be powered from different sources for ultimate redundancy Available with M12 Mini Change or M23 style connectors CSA UL 60950 1 safety approved to 85 C 185 F Simple Plug and Play Operation Automatic learning of up to 8192 MAC addresses Auto negotiation on all 10 100Base TX ports 100FX on opt...

Страница 13: ...10 9 11 Figure 1 RUGGEDCOM RS969 M12 Connectors Shown 1 Copper Ethernet Ports 2 Port Status LED 3 POWER 1 LED 4 POWER 2 LED 5 ALARM LED 6 RS 232 Console Port 7 Failsafe Output Relay 8 M12 Power Supply Port 9 Fiber Optic Ethernet Ports 10 Surge Ground Connection 11 Chassis Ground Connection ...

Страница 14: ...M RS969 RJ45 Connectors Shown 1 Copper Ethernet Ports 2 Port Status LED 3 POWER 1 LED 4 POWER 2 LED 5 ALARM LED 6 RS 232 Console Port 7 Failsafe Output Relay 8 M23 Power Supply Port 9 Fiber Optic Ethernet Ports 10 Surge Ground Connection 11 Chassis Ground Connection Port Status LED Indicate the status of each port ...

Страница 15: ...ng to the Device Copper Fiber Ethernet Ports For information about available copper and fiber Ethernet ports refer to Chapter 4 Communication Ports Section 1 3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS969 Tools Materials Purpose AC or DC power cord 16 AWG For connecting power to the device CAT 5 Ethernet cables For connecting the device...

Страница 16: ... 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized Section 1 5 Ingress Protection IEC International Standard 60529 Edition 2 1 2001 02 is a classification of degrees of protection provided by enclosures as a system for specifying the enclosures of electrical equipment on the basis of the degree of protection provided by the ...

Страница 17: ...ng This device may include sensitive proprietary data Before taking the device out of service either permanently or for maintenance by a third party make sure it has been fully decommissioned For more information refer to the associated User Guide Recycling and Disposal For environmentally friendly recycling and disposal of this device and related accessories contact a facility certified to dispos...

Страница 18: ...Chapter 1 Introduction RUGGEDCOM RS969 Installation Guide 8 Decommissioning and Disposal ...

Страница 19: ...e IMPORTANT This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be installed in a restricted acce...

Страница 20: ...r damaged contact Siemens for assistance Section 2 3 Mounting the Device The RUGGEDCOM RS969 is designed to be mounted on a panel by affixing the top and bottom flanges of the device to a panel using screws IMPORTANT Heat generated by the device is channeled outwards from the enclosure As such it is recommended that 2 5 cm 1 in of space be maintained on all open sides of the device to allow for so...

Страница 21: ... Connecting the Failsafe Alarm Relay The Failsafe output relay is provided to signal critical error conditions that may occur on the RUGGEDCOM RS969 series switches The contacts are energized upon power up of the unit and remain energized until a critical error occurs One common application for this output is to signal an alarm if a power failure or removal of control power occurs The proper relay...

Страница 22: ...o the RUGGEDCOM RS969 with the Mini power connector The M23 power connector has five terminal pins which allows for two power supply sources to be connected to the RUGGEDCOM RS969 with the M23 power connector When equipped with an M23 power connector the RUGGEDCOM RS969 supports dual redundant power supplies Power Supply 1 PS1 and Power Supply 2 PS2 CONTENTS Section 2 5 1 Power Supply Connector Pi...

Страница 23: ...rotection 4 PS1 Neutral PS1 Neutral is connected to the negative terminal if the power source is DC or to the Neutral terminal if the power source is AC M23 Power Supply Connector 5 4 3 2 1 Figure 7 M23 Power Supply Connector Terminal Description Usage 1 PS1 Live PS1 Live is connected to the positive terminal if the power source is DC or to the Live terminal if the power source is AC 2 PS1 Neutral...

Страница 24: ...lies NOTE For 100 240 VAC rated equipment a 250 VAC appropriately rated circuit breaker must be installed For 88 300VDC rated equipment a 300VDC appropriately rated circuit breaker must be installed A circuit breaker is not required for 12 24 or 48 VDC rated power supplies For dual power supplies separate circuit breakers must be installed and separately identified When equipped with two HI voltag...

Страница 25: ...Supply Wiring Example M23 Power Connector 1 M23 Power Connector 2 Neutral 3 Safety 4 Line 5 250 VAC Breaker 6 110 230 VAC Power Source 7 Safety Earth Single Low DC Power Supply Wiring 4 1 2 3 2 1 4 3 Figure 10 DC Power Supply Wiring Example Mini Change Connector 1 Mini Power Connector 2 Ground Bus 3 300 VDC Breaker 4 DC Power Source ...

Страница 26: ...3 Connector 1 M23 Power Connector 2 Ground Bus 3 300 VDC Breaker 4 DC Power Source Dual AC DC Power Supply Wiring M23 Connector Only 1 2 6 4 5 8 4 5 3 2 1 7 4 5 3 3 Figure 12 AC and AC Power Supply Wiring Example 1 M23 Power Connector 2 Ground Bus 3 Line 4 250 VAC Breaker 5 Neutral 6 110 230 VAC Power Source PS2 7 110 230 VAC Power Source PS1 8 Safety ...

Страница 27: ...er 9 DC Power Source PS1 3 2 1 4 5 1 2 3 5 3 4 Figure 14 DC and DC Power Supply Wiring Example 1 M23 Power Connector 2 Ground Bus 3 300 VDC Breaker 4 DC Power Source PS2 5 DC Power Source PS1 Section 2 5 3 Disabling Line to Ground Transient Protection All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the inputs to be isolated from ground remov...

Страница 28: ...Chapter 2 Installing the Device RUGGEDCOM RS969 Installation Guide 18 Disabling Line to Ground Transient Protection Figure 15 Surge Ground Chassis Ground Connection ...

Страница 29: ... PC or terminal directly to the RS 232 console port to access the boot time control and ROS interfaces The console port provides access to ROS s console and Web interfaces IMPORTANT The console port is intended to be used only as a temporary connection during initial configuration or troubleshooting Connection to the console port is made using an M12 to DB9 console cable The following is the pin o...

Страница 30: ...actory default IP address for the RUGGEDCOM RS969 is https 192 168 0 1 For more information about available ports refer to Chapter 4 Communication Ports Section 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM ROS interface For more information about configuring the device refer to the ...

Страница 31: ... determine which ports are equipped on the device refer to the factory data file available through ROS For more information on how to access the factory data file refer to the ROS User Guide for the RUGGEDCOM RS969 Each communication port type has a specific place in the RUGGEDCOM RS969 chassis 2 1 Figure 17 Port Assignment M12 Connectors Shown 1 M12 D Coded Copper Ethernet Ports 2 Fiber Optic Eth...

Страница 32: ...OM RS969 supports eight 10 100Base TX Ethernet ports that allow connection to standard Category 5 CAT 5 unshielded twisted pair UTP cables with RJ45 male connectors or M12 male connectors The RJ45 M12 connectors are directly connected to chassis ground on the device and can accept CAT 5 shielded twisted pair STP cables WARNING Electric shock hazard risk of serious personal injury and or equipment ...

Страница 33: ... Data 4 Reserved Do Not Connect 5 Reserved Do Not Connect 6 TX Transmit Data 7 Reserved Do Not Connect 8 Reserved Do Not Connect Pin Out M12 The following is the pin out description for the M12 connectors Figure 20 4 Pin D Coded M12 Ethernet Port Pin Configuration Pin 10 100Base Tx Signal 1 TX 2 RX 3 TX 4 RX Specifications For specifications on the available copper Ethernet ports refer to Section ...

Страница 34: ...DCOM RS969 Installation Guide 24 Fiber Optic Ethernet Ports 2 1 Figure 21 LC Port 1 Tx Connector 2 Rx Connector For specifications on the available fiber optic Ethernet ports refer to Section 5 4 Fiber Optic Ethernet Port Specifications ...

Страница 35: ...on 5 6 Mechanical Specifications Section 5 7 Dimension Drawings Section 5 1 Power Supply Specifications Power Supply Type Minimum Input Maximum Input Internal Fuse Rating Isolation Maximum Power Consumption 12 24 VDC 10 VDC 36 VDC 24 VDC 18 VDC 36 VDC 48 VDC 36 VDC 72 VDC 1 5 kVDC HI 125 250 VDC b 88 VDC 300 VDC 4 kVAC HI 110 230 VAC b 85 VAC 265 VAC 3 15A T a 5 5 kVDC 10 W a T denotes time delay ...

Страница 36: ...et Optical Specifications Tx dBm Mode Connector Cable Type µm Tx λ nm c Min Max Rx Sensitivity dBm Rx Saturation dBm Typical Distance km Power Budget dB SM LC 9 125 1300 15 8 32 3 20 17 SM LC 9 125 1300 5 0 35 3 50 30 SM LC 9 125 1300 0 5 37 0 90 37 MM LC 50 125 850 22 5 14 31 14 2 8 5 c Typical Gigabit Ethernet Optical Specifications NOTE All cabling is duplex type unless otherwise specified Maxi...

Страница 37: ...S969 is rated to operate under the following environmental conditions Ambient Operating Temperature e 40 to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity f 5 to 95 Maximum Altitude g 2000 m 6562 ft e Measured from a 30 cm 12 in radius surrounding the center of the RUGGEDCOM RS969 enclosure f Non condensing g Over temperature range of 40 to 85 C 40 to...

Страница 38: ...Chapter 5 Technical Specifications RUGGEDCOM RS969 Installation Guide 28 Dimension Drawings Figure 22 M12 Connectors ...

Страница 39: ...RUGGEDCOM RS969 Installation Guide Chapter 5 Technical Specifications Dimension Drawings 29 Figure 23 RJ45 Connectors ...

Страница 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS969 Installation Guide 30 Dimension Drawings ...

Страница 41: ...TENTS Section 6 1 Power 1 unit Section 6 2 Console 1 unit Section 6 3 Failsafe 1 unit Section 6 4 Ethernet 8 unit Section 6 5 LC Fiber Optic 2 unit Section 6 1 Power 1 unit M23 Power Mating Connector Figure 24 M23 Power Mating Connector Description M23 5pin female connector 600V IP68 rated Order Code 99 60 0007 Cable Specifications 3 18 AWG jacket OD range 0 20 0 48 ...

Страница 42: ...ion MINI Change 4pin female connector 4 16AWG rubber Order Code P N 99 43 0183 001 Section 6 2 Console 1 unit M12 Console Port Mating Cable Figure 26 M12 Console Port Mating Cable Description M12 8pin A code male to DB9 female unshielded PUR jacket cable 30V 4A 3m Order Code 99 43 0023 001 Cable Specifications M12 8pin A code male to free end 3m ...

Страница 43: ...r Figure 27 M12 Console Port Mating Connector Description M12 straight plug 8 pole A coded IP67 rated Order Code 99 60 0002 Section 6 3 Failsafe 1 unit M12 FailSafe Port Mating Cable Figure 28 M12 FailSafe Port Mating Cable Description M12 4pole A coded unshielded PUR Jacket cable 3m Order Code 99 43 0024 001 ...

Страница 44: ...t Mating Connector Description M12 straight plug 4 pole A coded IP67 rated Order Code 99 60 0009 Section 6 4 Ethernet 8 unit M12 D code Ethernet Port Mating Cable Figure 30 M12 D code Ethernet Port Mating Cable Description M12 D code to RJ45 patch cable 3meters Order Code 99 43 0040 001 Cable Specifications M12 D code male 4 pin CAT5e 3m ...

Страница 45: ...net Port Mating Connector Description M12 straight plug 4 pole D coded IP67 rated Order Code 99 60 0008 M12 D Code Ethernet Port Mating Cable Figure 32 M12 D Code Ethernet Port Mating Cable Description M12 male D code to male D code shielded PUR jacket patch cable 5 meters Order Code 99 43 0041 001 Cable Specifications M12 male 4 pin CAT 5e 5m ...

Страница 46: ...ng Cable Figure 33 IP67 RJ45 Ethernet Port Mating Cable Description IP67 RJ45 plug to RJ45 CAT5e shielded patch cable 3 1m Order Code 99 43 0182 001 IP67 RJ45 Ethernet Port Mating Connector Figure 34 IP67 RJ45 Ethernet Port Mating Connector Description IP67 RJ45 plug field attachable Order Code 30 50 0019 ...

Страница 47: ...r Optic 2 unit 37 Section 6 5 LC Fiber Optic 2 unit LC Port Mating Connector Figure 35 LC Port Mating Connector Description IP67 Multimode LC plug Order Code 99 60 0006 Figure 36 LC Port Mating Connector Description IP67 Singlemode LC plug Order Code 99 60 0002 001 ...

Страница 48: ... Optic 2 unit LC Port Mating Connector Figure 37 LC Port Mating Connector Description Multimode IP67 LC plug to LC connector 3m Order Code 99 43 0056 001 Figure 38 LC Port Mating Connector Description Singlemode IP67 LC plug to LC connector 3m Order Code 99 43 0054 001 ...

Страница 49: ...n details the standards to which the RUGGEDCOM RS969 complies CONTENTS Section 7 1 1 CSA Section 7 1 2 European Commission EC Section 7 1 3 FCC Section 7 1 4 FDA CDRH Section 7 1 5 ISED Section 7 1 6 ACMA Section 7 1 7 RoHS Section 7 1 8 Other Approvals Section 7 1 1 CSA This device meets the requirements of the following Canadian Standards Association CSA standards under certificate 16 70065161 C...

Страница 50: ... used throughout the European community A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd For contact information refer to Contacting Siemens Section 7 1 3 FCC This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter...

Страница 51: ...tions Compliance Labelling Electromagnetic Radiation Notice 2003 made under Section 182 of the Radiocommunications Act 1992 Telecommunications Labelling Customer Equipment and Customer Cabling Notice 2001 made under Section 407 of the Telecommunication Act 1997 The device is marked with an RCM symbol to indicate compliance when sold in the Australian region A copy of the Declaration of Conformity ...

Страница 52: ...nts NEMA TS 2 Traffic Controller Assemblies with NTCIP Requirements MIL S 901D MIL S 901D Military Specification Shock Tests H I High Impact Shipboard Machinery Equipment and Systems Requirements For Section 7 2 MIL STD Test Specifications Test Description MIL STD 167 Vibration Navy MIL STD 167 1 Type I CE101 DC 28V CE102 AC 115V RE101 RE102 1 Surface Ship Applications RE102 2 Submarine Applicatio...

Страница 53: ...ests The RUGGEDCOM RS969 has passed the following EMC and environmental tests IEC 61850 3 Type Tests Test Description Test Levels Severity Levels Enclosure Contact 8 kV 4 IEC 61000 4 2 ESD Enclosure Air 15 kV 4 IEC 61000 4 3 Radiated RFI Enclosure ports 20 V m x Signal ports 4 kV 2 5 kHz x DC Power ports 4 kV 4 AC Power ports 4 kV 4 IEC 61000 4 4 Burst Fast Transient Earth ground ports 4 kV 4 Sign...

Страница 54: ...le on DC Power Supply DC Power ports 10 3 Signal ports 2 kV Fail Safe Relay output DC Power ports 1 5 kV IEC 60255 5 Dielectric Strength AC Power ports 2 kV Signal ports 5 kV Fail Safe Relay output DC Power ports 5 kV IEC 60255 5 HV Impulse AC Power ports 5 kV IEEE 1613 Type Tests NOTE If the unit contains copper ports the IEEE 1613 conformance is Class 1 during disturbance errors may occur but re...

Страница 55: ...ibration levels are very high e g shipboard application and for severe transportation conditions Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60255 21 1 Vibration 2g 10 150 Hz Class 2 IEC 60255 21 2 S...

Страница 56: ...Chapter 7 Certification RUGGEDCOM RS969 Installation Guide 46 EMC and Environmental Type Tests ...

Отзывы: