Installing the Device
2.6.1 Connecting High AC/DC Power

• For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker

must be installed.

• Use minimum #16 gage copper wiring when connecting terminal blocks.
• Equipment must be installed according to applicable local wiring codes and

standards.

2.6.1

Connecting High AC/DC Power

To connect a high AC/DC power supply to the device, do the following:

NOTICE

Electrical hazard – risk of damage to equipment

Do not connect AC power cables to terminals for DC power. Damage to the power

supply may occur.

NOTICE

Electrical hazard – risk of damage to equipment

Before testing the dielectric strength (HIPOT) in the field, remove the braided

ground cable connected to the surge ground terminal and chassis ground. This cable

connects transient suppression circuitry to chassis ground and must be removed to

avoid damage to transient suppression circuitry during testing.

12

RUGGEDCOM RS900G

Installation Manual, 01/2021, C79000-G8976-1025-08

Содержание RUGGEDCOM RS900G

Страница 1: ...Edition 01 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS900G https www siemens com ...

Страница 2: ...ed Ethernet Switches RUGGEDCOM RS900G Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Communication Ports 4 Technical Specifications 5 Certification 6 01 2021 C79000 G8976 1025 08 ...

Страница 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Страница 4: ...stalling the Device in Hazardous Locations 6 2 4 Mounting the Device 7 2 4 1 Mounting the Device on a DIN Rail 7 2 4 2 Mounting the Device to a Panel 9 2 5 Connecting the Failsafe Alarm Relay 11 2 6 Connecting Power 11 2 6 1 Connecting High AC DC Power 12 2 6 2 Connecting Low DC Power 14 3 Device Management 17 3 1 Connecting to the Device 17 3 2 Configuring the Device 18 4 Communication Ports 19 4...

Страница 5: ...nvironment 25 5 6 Mechanical Specifications 25 5 7 Dimension Drawings 25 6 Certification 29 6 1 Approvals 29 6 1 1 CSA 29 6 1 2 European Union EU 30 6 1 3 FCC 30 6 1 4 FDA CDRH 31 6 1 5 ISED 31 6 1 6 ISO 31 6 1 7 ACMA 31 6 1 8 RoHS 32 6 1 9 Other Approvals 32 6 2 EMC and Environmental Type Tests 32 iv RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 6: ... Trademarks RUGGEDCOM and ROS are trademarks of Siemens AG Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Warranty Siemens warrants this product for a period of five 5 years from the date of purchase conditional upon the return to factory for maintenance during the warranty term This product contains no...

Страница 7: ...d with domain knowledge in the utility transportation and industrial markets allows Siemens to provide training specific to the customer s application For more information about training services and course availability visit https www siemens com or contact a Siemens Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical ...

Страница 8: ... Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 vii ...

Страница 9: ...Preface Contacting Siemens viii RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 10: ...anced networking features such as Enhanced Rapid Spanning Tree eRSTP Port Rate Limiting and a full array of intelligent functionality for high network availability and manageability 1 1 Feature Highlights Ethernet Ports 2 x 1000Base X fiber optic ports 8 x 10 100Base TX RJ45 ports Industry standard fiber optic connectors LC SC and SFP pluggable optics Bi directional simplex fiber support Long haul...

Страница 11: ...ive and transmit network traffic as well as provide remote Web access to the RUGGEDCOM RS900G operating system For more information refer to Connecting to the Device Page 17 Communication Ports Page 19 RS 232 Console Port The serial console port is for interfacing directly with the device and accessing initial management functions For information about connecting to the device via the serial conso...

Страница 12: ...ce to a panel 4 x M3 5 6 32 screws For mounting the device to a panel 1 4 Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment Decommissioning This device may include sensitive proprietary data Before taking the device out of service either permanently or for mai...

Страница 13: ...h MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized 4 RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 14: ...date specifications test results and agency approvals and void the user s authority to operate the equipment IMPORTANT This product should be installed in a restricted access location where access can only be gained by authorized personnel who have been informed of the restrictions and any precautions that must be taken Access must only be possible through the use of a tool lock and key or other m...

Страница 15: ...ormal operating environments IMPORTANT The device is certified for installation in hazardous environments as a component only It is required to be installed in a suitable enclosure where the final combination is subject to acceptance by an authorized local inspection authority Installation and use of the device in a hazardous location should meet the following special conditions for safe use The d...

Страница 16: ...of the device to allow for some convectional airflow Forced airflow is not required However any increase in airflow will result in a reduction of ambient temperature and improve the long term reliability of all equipment mounted in the rack space Note For detailed dimensions of the device with either DIN rail or panel hardware installed refer to Dimension Drawings Page 25 2 4 1 Mounting the Device...

Страница 17: ... sliding release with a slot at the bottom for a flathead screwdriver 1 2 2 3 1 1 1 DIN Rail 2 DIN Rail Adapter Figure 2 1 Mounting the Device to a DIN Rail 2 Insert a flathead screw driver into the slot of the sliding release and move it down 3 Push the device against the bottom of the DIN rail 4 Let go of the sliding release to latch the device 8 RUGGEDCOM RS900G Installation Manual 01 2021 C790...

Страница 18: ... 1 2 1 3 1 DIN Rail 2 DIN Rail Adapter Figure 2 2 Removing the Device from a DIN Rail 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 2 4 2 Mounting the Device to a Panel For panel installations the RUGGEDCOM RS900G can be equipped with panel adapters that allow the device to be attached to a panel using screws RUGGEDCOM RS900G Installation Manual 01 2021...

Страница 19: ...l Adapter 2 Screw Figure 2 3 Installing the Panel Adapters 2 For both adapters align the slots with the screws and then slide the adapters onto the device 3 Tighten the screws to secure the adapters 4 Place the device against the panel and align the adapters with the mounting holes 2 1 2 1 1 Panel Adapter 2 Screw Figure 2 4 Panel Mounting 10 RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G897...

Страница 20: ...through RUGGEDCOM RS900G One common application for this relay is to signal an alarm if a power failure occurs For more information refer to the RUGGEDCOM RS900G User Guide for the RUGGEDCOM RS900G The following shows the proper relay connections 1 2 3 1 Normally Closed 2 Common 3 Normally Open Figure 2 5 Failsafe Alarm Relay Wiring 2 6 Connecting Power The RUGGEDCOM RS900G features an integrated ...

Страница 21: ... the following NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to terminals for DC power Damage to the power supply may occur NOTICE Electrical hazard risk of damage to equipment Before testing the dielectric strength HIPOT in the field remove the braided ground cable connected to the surge ground terminal and chassis ground This cable connects transient suppres...

Страница 22: ... the negative wire from the power source to the negative neutral N terminal on the terminal block 3 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal on the power sour...

Страница 23: ...terminal block or Euroblock to one of the available terminals 2 Connect the positive wire from the power source to the positive terminal on the terminal block 1 3 2 4 1 Positive Terminal 2 Negative Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 7 Terminal Block Wiring Single DC Power Supply Inputs 3 Connect the negative wire from the power source to the negative terminal on the t...

Страница 24: ... Connect the ground terminal on the power source to the chassis ground terminal on the device 6 If a redundant power source is required repeat Step 1 to Step 5 using the second terminal RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 15 ...

Страница 25: ...Installing the Device 2 6 2 Connecting Low DC Power 16 RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 26: ...al console port to access the boot time control and RUGGEDCOM ROS console interface IMPORTANT The serial console port is intended to be used only as a temporary connection during initial configuration or troubleshooting and should only be used in a safe area as defined by IEC 60079 0 Edition 6 0 The serial console port implements RS 232 DCE Data Communication Equipment on a DB9 connector Use the f...

Страница 27: ...net ports on the device to a management switch and access the RUGGEDCOM RS900G console and Web interfaces via the device s IP address The factory default IP address for the RUGGEDCOM RS900G is https 192 168 0 1 For more information about available ports refer to Communication Ports Page 19 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured Al...

Страница 28: ...et Ports The RUGGEDCOM RS900G features eight 10 100Base TX copper RJ45 Ethernet ports that allow connection to standard Category 5 CAT 5 unshielded twisted pair UTP cables with RJ45 male connectors Each port is directly connected to the chassis ground on the device and can accept CAT 5 Unshielded Twisted Pair UTP or Shielded Twisted Pair STP cables WARNING Electric shock hazard risk of serious per...

Страница 29: ...igure 4 3 RJ45 Port Pin Configuration Pin Name Description 1 RX Receive Data 2 RX Receive Data 3 TX Transmit Data 4 Reserved Do Not Connect 5 Reserved Do Not Connect 6 TX Transmit Data 7 Reserved Do Not Connect 8 Reserved Do Not Connect Specifications For further specifications refer to Copper Ethernet Port Specifications Page 24 4 2 Fiber Optic Ethernet Ports Optional 1000Base SX and 1000Base LX ...

Страница 30: ...en Blinking Link activity Off No link detected Specifications For further specifications refer to Fiber Optic Ethernet Port Specifications Page 24 4 3 SFP Transceivers The RUGGEDCOM RS900G supports up to two Small Form Factor Pluggable SFP transceiver sockets which are compatible with a wide array of SFP transceivers available from Siemens LEDs Each socket features an LED that indicates its link s...

Страница 31: ...g and installation removal refer to the RUGGEDCOM SFP Transceiver Catalog https support industry siemens com cs ca en view 109482309 IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products Siemens accepts no liability as a result of performance issues related in whole or in part to third party components 22 RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 32: ...ay fuse b Power consumption varies based on configuration Non Hazardous Environments Power Supply Type Minimum Input Maximum Input Fuse Rating Isolation Maximum Power Consumption 12 24 VDC 10 VDC 36 VDC 3 15A T a 1 5 kVDC 24 VDC 18 VDC 36 VDC 3 15A T a 1 5 kVDC 48 VDC 37 VDC 72VDC 3 15A T a 1 5 kVDC HI 125 250 VDC b HI 110 230 VAC b 88 VDC 85 VAC 300 VDC 265 VAC 3 15A T a 4 kVAC 5 5 kVDC 10 W a T ...

Страница 33: ...istance d Isolation RJ45 FDX HDX CAT 5 TIA EIA T568A B 100 m 328 ft 1 5 kV micro D FDX HDX CAT 5 TIA EIA T568A B 100 m 328 ft 1 5 kV a Auto Negotiating b Shielded or unshielded c Auto crossover and auto polarity d Typical distance Dependent on the number of connectors and splices 5 4 Fiber Optic Ethernet Port Specifications The following details specifications for all optional fixed fiber optic Et...

Страница 34: ...F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude d 2000 m 6562 ft a Measured from a 30 cm 12 in radius surrounding the center of the RUGGEDCOM RS900G enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing d Over tempera...

Страница 35: ...Technical Specifications 5 7 Dimension Drawings 65 1 116 6 169 0 188 0 7 9 99 1 Figure 5 1 Overall Dimensions 26 RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 36: ...cal Specifications 5 7 Dimension Drawings 13 7 194 1 78 7 120 7 101 6 129 9 11 2 183 9 89 6 Figure 5 2 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 27 ...

Страница 37: ...Technical Specifications 5 7 Dimension Drawings 28 RUGGEDCOM RS900G Installation Manual 01 2021 C79000 G8976 1025 08 ...

Страница 38: ...ipment Safety Part 1 General Requirements CAN CSA C22 2 No 0 M91 General Requirements Canadian Electrical Code Part II CAN CSA C22 2 No 142 M1987 Process Control Equipment Industrial Products CAN CSA C22 2 No 213 16 Nonincendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Bi National Standard with ANSI ISA 12 12 01 2016 U...

Страница 39: ...581 Technical Documentation for the Assessment of Electrical and Electronic Products with Respect to the Restriction of Hazardous Substances EN 55022 Information Technology Equipment Radio Disturbance Characteristics Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community A copy of the CE Declaration of Conformity is available from...

Страница 40: ... Siemens AG to meet the requirements of the following ISED Innovation Science and Economic Development Canada standard CAN ICES 3 A NMB 3 A 6 1 6 ISO This device was designed and manufactured using a certified ISO International Organization for Standardization quality program that adheres to the following standard ISO 9001 2015 Quality management systems Requirements 6 1 7 ACMA This device meets t...

Страница 41: ...trical and electronic equipment China RoHS 2 Administrative Measure on the Control of Pollution Caused by Electronic Information Products A copy of the Material Declaration is available online at https support industry siemens com cs ww en view 109738831 6 1 9 Other Approvals This device meets the requirements of the following additional standards EN50121 4 Railway applications Electromagnetic Com...

Страница 42: ...ted RFI Earth Ground Ports 10 V 3 IEC 61000 4 8 Magnetic Field Enclosure Ports 40 A m Continuous 1000 A m for 1 s DC Power Ports 30 for 0 1 s 100 for 0 02 s 100 for 0 05 s IEC 61000 4 29 Voltage Dips and Interrupts AC Power Ports 30 for 1 Period 60 for 50 Periods IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 100 for 5 Periods 100 for 50 Periods Signal Ports 2 5 kV Common Mode 1 MHz 1 k...

Страница 43: ...ure Contact 8 kV ESD Enclosure Air 15 kV Radiated RFI Enclosure Ports 35 V m Signal Ports 4 kV 2 5 kHz DC Power Ports 4 kV AC Power Ports 4 kV Fast Transient Earth Ground Ports 4 kV Signal Ports 2 2 kV Common Mode 1 MHz DC Power Ports 2 5 kV Common and Differential Mode 1 MHz Oscillatory AC Power Ports 2 5 kV Common and Differential Mode 1 MHz Signal Ports 5 kV Failsafe Relay DC Power Ports 5 kV H...

Страница 44: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...

Отзывы: