Connecting the Failsafe Alarm Relay
2
1
2
1
Figure 4: Panel Mounting
1.
Screw
2.
Panel Mount Adapter
3. Secure the adapters to the panel with #6-32 screws.
Section 2.5
Connecting the Failsafe Alarm Relay
The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed
when the unit is powered and there are no active alarms. If the device is not powered or if an active alarm is
configured, the relay opens the NO contact and closes the NC (Normally Closed) contact.
NOTE
Control of the failsafe relay output is configurable through ROS-F. One common application for this
relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS-F User
Guide for the RUGGEDCOM RS900F.
To connect the failsafe alarm relay, do the following:
1. Insert the failsafe alarm relay terminal block into the device and tighten the screws.
2. Connect a failsafe device to the terminal block.
Содержание RUGGEDCOM RS900F
Страница 4: ...RUGGEDCOM RS900F Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900F Installation Guide x Customer Support ...
Страница 16: ...Chapter 1 Introduction RUGGEDCOM RS900F Installation Guide 6 Tamper Evident Security Seals ...
Страница 28: ...Chapter 2 Installing the Device RUGGEDCOM RS900F Installation Guide 18 Connecting Low DC Power ...
Страница 34: ...Chapter 4 Communication Ports RUGGEDCOM RS900F Installation Guide 24 Fiber Optic Ethernet Ports ...
Страница 48: ...Chapter 6 Certification RUGGEDCOM RS900F Installation Guide 38 EMC and Environmental Type Tests ...