Mounting the Device
9
60079-0 and CSA/UL/IEC/EN 60079-15. The enclosure shall have a minimum service temperature range of -40 to
100 °C (-40 to 212 °F).
• The equipment shall be used in an area of not more than pollution degree 2 as defined in IEC/EN 60664-1.
• The serial DB9 console port shall only be used in the safe area.
• The equipment must be appropriately connected to safety Earth upon installation.
NOTE
For further details of the device's compliance with Class I, Division 2, Zone 2 standards, refer to
IMPORTANT!
Do not disconnect or open equipment unless power has been switched off or the area is known to be
non-hazardous.
IMPORTANT !
Débrancher ou ouvrir l'équipment seulement si l'alimnetation a été coupée ou si l'on sait que la zone
ne pose aucun danger.
IMPORTANT!
Substitution of the components may impair suitability for Class I, Division 2.
IMPORTANT !
Le remplacement de composants pourrait compromettre l'admissibilité à la Classe I, Division 2.
Sample Hazardous Location Label
The following is an example of the RUGGEDCOM RS900F hazardous location label:
Figure 2: Compliance Label (Example)
Section 2.4
Mounting the Device
The RUGGEDCOM RS900F is designed for maximum mounting and display flexibility. It can be equipped with
adapters that allow it to be installed on a 35 mm (1.4 in) DIN rail or affixed to a panel.
Содержание RUGGEDCOM RS900F
Страница 4: ...RUGGEDCOM RS900F Installation Guide iv ...
Страница 10: ...Preface RUGGEDCOM RS900F Installation Guide x Customer Support ...
Страница 16: ...Chapter 1 Introduction RUGGEDCOM RS900F Installation Guide 6 Tamper Evident Security Seals ...
Страница 28: ...Chapter 2 Installing the Device RUGGEDCOM RS900F Installation Guide 18 Connecting Low DC Power ...
Страница 34: ...Chapter 4 Communication Ports RUGGEDCOM RS900F Installation Guide 24 Fiber Optic Ethernet Ports ...
Страница 48: ...Chapter 6 Certification RUGGEDCOM RS900F Installation Guide 38 EMC and Environmental Type Tests ...