Installing Device
2.6.3 Wiring Examples
3. Connect the positive wire from the power source to terminal 5 (+/L) on the
terminal block.
3
4
3
4
1
2
3
3
1
1
Screw-Type Terminal Block
2
Pluggable Terminal Block
3
Jumper
4
Terminal 4 (Chassis Ground)
5
Terminal 5 (+/L)
6
Terminal 7 (-/N)
7
Chassis Ground Terminal
Figure 2.7
Terminal Block Wiring
4. Connect the negative wire from the power source to terminal 7 (-/N) on the
terminal block.
5. If the external PoE power supply features a chassis ground connection, connect
the ground terminal on the power supply to terminal 4 on the terminal block.
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the
device is powered.
6. Install the terminal block cover.
2.6.3
Wiring Examples
The following illustrate how to connect power to single and dual power supplies.
RUGGEDCOM RS416PF
Installation Manual, 04/2021, C79000-G8976-1355-04
19