Certification
5.2 EMC and Environmental Type Tests
5.2
EMC and Environmental Type Tests
The RUGGEDCOM RMC20 has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
Test
Description
Test Levels
Severity
Levels
Enclosure
Contact
± 8 kV
4
IEC
61000-4-2
ESD
Enclosure Air
± 15 kV
4
IEC
61000-4-3
Radiated RFI
Enclosure
Ports
20 V/m
Note
Signal Ports
± 4 kV @ 2.5 kHz
Note
DC Power
Ports
± 4 kV
4
AC Power
Ports
± 4 kV
4
IEC
61000-4-4
Burst (Fast Transient)
Earth
Ground Ports
± 4 kV
4
Signal Ports
± 4 kV Line-to-Earth,
± 2 kV Line-to-Line
4
DC Power
Ports
± 2 kV Line-to-Earth,
± 1 kV Line-to-Line
3
IEC
61000-4-5
Surge
AC Power
Ports
± 4 kV Line-to-Earth,
± 2 kV Line-to-Line
4
Signal Ports
10 V
3
DC Power
Ports
10 V
3
AC Power
Ports
10 V
3
IEC
61000-4-6
Induced (Conducted) RFI
Earth
Ground Ports
10 V
3
40 A/m continuous,
1000 A/m for 1 s
IEC
61000-4-8
Magnetic Field
Enclosure
Ports
1000 A/m for 1 s
5
DC Power
Ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC
61000-4-29
30% for 1 period,
60% for 50 periods
IEC
61000-4-11
Voltage Dips and Interrupts
AC Power
Ports
100% for 5 periods,
100% for 50 periods
Signal Ports
2 kV (Fail-Safe
Relay output)
DC Power
Ports
1.5 kV
IEC 60255-5
Dielectric Strength
AC Power
Ports
2 kV
30
RUGGEDCOM RMC20
Installation Manual, 04/2021, C79000-G8976-1007-10