![Siemens MOBY I ASM 421 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/siemens/moby-i-asm-421/moby-i-asm-421_technical-description_377253007.webp)
ASM 421 Technical Description
6GT2 097-3AH00-0DA2
– 5 –
RD: 03/02
6GT2 002-0DA00
ASM 421 / V.24
Subject to change without notice!
6GT2 002-0DB00
ASM 421 / RS422
6GT2 002-0DC00
ASM 421 / TTY
J31069-D0142-U001-A0-7618
2
ASM 421 hardware
CPU
EPROM
Backplane connector (X1)
Fuse
(T 315 mA)
Switch bank (S1)
for setting mode of operation
3 LEDs:
red
LED: indicates a fault (see table in chap. 7)
yellow LED: indicates that the SLG device is active
green LED: indicates that an MDS is present
9–way subminiature D connector (screw locking)
(X2) for connecting the SLG read/write device
(The SLG can also be connected via the back–
plane connector if required).
Pin
Function
1
2
3
4
5
6
7
8
9
reserve
+ transmit
+ receive
reserve
– receive
– transmit
ground () V)
+ 24 V
reserve
housing
cable screen
Pin assignments to SLG
MOBY
Error
Active
ANW
housing = connector housing