Process Values (R41,010 – R41,048)
Rate and Total (R41,010 – R41,019)
The associated registers provide the readings of rate. Totalizer 1 and Totalizer 2 in
engineering units as displayed in the local SF 500 display.
Device State (41,020 – 41,020)
The Device State word is used to feedback the current operating state of the product.
Each bit gives the state of different parts of the product, some mutually exclusive, others
are not. The state should be checked to verify any device commands.
Bit #
Description
Bit Clear
Bit Set (1)
1
PID 1 Mode
Manual
Auto
2
PID 1 Freeze
No
Yes
3
PID 1 Setpoint Source
Local
Remote
4
PID 2 Mode
Manual
Auto
5
PID 2 Freeze
No
Yes
6
PID 2 Setpoint Source
Local
Remote
7
Zero
No
In progress
8
Span
No
In progress
9
-
-
-
10
-
-
-
11
-
-
-
12
-
-
-
13
Write Privileges
No
Yes
14
System Configured
Not Configured
Yes
15
Mode
Calibration Mode
RUN Mode
16
Totalizing
Not Totalizing
Totalizing