7ML19985CN01
Milltronics SF 500 - INSTRUCTION MANUAL
Page 55
mmm
mm
PI
D Co
nt
ro
l
Setpoint Controller – Rate and Additive Control
Default Value =
f
Comments:
1.
Connect primary rate controlled device to mA O/P 2
Connect additive rate controlled device to mA O/P 3
Connect additive process variable to mA I/P
Hardwire mA O/P 1 to mA O/P 2
2.
Ratio of Additive to Primary product may be adjusted by changing P418-02
Parameter
Index
Choices
01
02
03
Controller Selection
P400-
1
1
----
0=Off, 1=Man, 2=Auto
Process Variable Source
P402-
1
f
2
----
1=Rate, 2=mA I/P 1,
3=mA I/P 2
Setpoint Configuration
P414-
0
2
----
0=Local, 1=mA I/P 1,
2=mA I/P 2
mA O/P Function
P201-
1
f
2
2
1=Rate, 2=PID
mA I/P Function
P255-
2
1
----
0=Off, 1=PID Set-
point, 2=PID Process
Variable
Remote Ratio
P418-
100
f
100
f
----
Setpoint=% of input
M
M
P
F
E N T E R
C L E A R
R E S E T
T O T A L
A L T
D I S P
R U N
P A R
Z E R O
S P A N
M
A
rotary feeder (primary product)
pump
additive
product
PID-01 O/P
PID-02 O/P
to mixing
device
liquids
flowmeter
motor
speed
controller
motor
speed
controller
Figure B
rate (PV)
flow (PV)