Page 114
Milltronics SF 500 - INSTRUCTION MANUAL
7ML19985CN01
mmmm
m
Pa
ra
m
et
er
s
P735 Back Light
Sets the intensity of the back light for the LCD. (
f
= 10)
Entry:
0 = OFF
1 to 10 = low to high
P739 Time Zone
The offset from Greenwich mean time (GMT) of local time.
This parameter does not affect any timed events because all times are local. It can be
accessed by a remote computer for synchronization purposes.
Enter local time zone –12 to 12
Communication (P750 - P799)
These parameters cover the various communications formats supported by the SF 500:
serial printer, Dolphin Plus, SmartLinx®, and Modbus.
P750 – P769 SmartLinx
®
Module Specific Parameters
These parameters are specific to the SmartLinx® module installed. Refer to the module
documentation for a list and description of the specific parameter requirements.
P770 – P789 Local Port Parameters
These parameters are specific to programming of the SF 500 communication ports. Refer
to
Communications
on page 69 for a listing and description of these parameters.
P790 SmartLinx
®
Error Status
Displays the results of ongoing hardware tests within the communications circuitry. If any
test does not meet the PASS requirements, communication halts and tests are repeated
until PASS requirements are met. Communication then resumes.
P791 Bus Error
Indicates if an error condition is occurring on the bus.
Values
Description
0
*
no error
Error Code
refer to the SmartLinx module documentation for explanation of the
code.