Parameters
12.9 Totalization (P619 - P648)
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
183
12.9.11
P680 Test Load: Weight (Options)
Selects the method by which the test load is entered into P017.
1 = enter value: returns to P017 for entry of the test load value. This value is calculated by the
formula: Total Mass of the test weights/average idler spacing
Example:
3 test weights each weighing 8.2 kg, idler spacing before the scale is 1225 mm, the idler spacing
after the scale is 1175 mm.
The average idler spacing is 1225 +1175/2=1200 mm or 1.2 m
Total mass of test weights/average idler spacing = 3X8.2 kg/1.2 m = 24.6/1.2 = 20.5 kg/m
2 = enter data: advances to P681 and P682 for entry of required data to automatically calculate
and enter the test load into P017.
12.9.12
P681 Total Mass of Test Weights
For test load data entry (P680=2) this parameter is enabled for entry of the total mass of all of
the test weights used for span calibration. The mass units are determined in P004 (imperial=1,
metric=2).
12.9.13
P682 Average Idler Spacing
For test load data entry (P680=2) this parameter is enabled for entry of the average idler space
before and afer the scale. On multiple scale idler systems, this includes the entire weigh area.
The length units are determined in P004 (imperial=1, metric=2).
12.9.14
P690 Speed Constant Entry
Selects the method by which the speed constant is entered, for both speed sensors (P690-01 or
02)
1)
.
1)
BW500/L has only one speed input
1 = calculated, this selection returns the program to appropriate P015 for entry of speed
constant:
(speed sensor pulses per revolution)/(pulley circumference (m or ft) / revolution)
e.g:
WS300-256 PPR mounted on 6” Bend Pulley
(256 pulses per revolution)/(0.478meters per revolution) = 534.694 pulses per meter or 162.975
pulses per feet
OR
2 = sensor data, the selection forwards the program to P691 and P692 for entry of the required
sensor data for automatic calculation. The calculated value is automatically entered into P015-01
or 02.
Содержание Milltronics BW500
Страница 1: ...Operating Instructions Milltronics BW500 and BW500 L 12 2016 Edition Integrators ...
Страница 12: ...Table of contents BW500 and BW500 L 10 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 14: ...Safety Notes BW500 and BW500 L 12 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 16: ...The Manual BW500 and BW500 L 14 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 48: ......
Страница 68: ...Start Up 6 4 Load Cell Balancing BW500 and BW500 L 66 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 108: ...Operation 8 10 Totalization BW500 and BW500 L 106 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 153: ...Communications 11 7 Error Handling BW500 and BW500 L Operating Instructions 12 2016 A5E33482052 AD 151 ...
Страница 154: ......
Страница 198: ...Troubleshooting 13 2 Specifically BW500 and BW500 L 196 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 208: ...Appendix A 3 Technical support BW500 and BW500 L 206 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 218: ...Index BW500 and BW500 L 216 Operating Instructions 12 2016 A5E33482052 AD ...
Страница 219: ......