6. SYSTEM PARAMETERS
Parameter Function
Range
[Default]
Description / Notes
G85139-H1751-U529-D1
© Siemens plc 1999
4/8/99
58
P112
Inverter type
1 - 8
[
¶¶¶
]
Read-only parameter.
1
= MICROMASTER 2nd Generation (MM2)
2
= COMBI MASTER
3
= MIDIMASTER
4
= MICROMASTER Junior (MMJ)
5
= MICROMASTER 3rd Generation (MM3)
6
= MICROMASTER Vector (MMV)
7
= MIDIMASTER Vector (MDV)
8 =
COMBIMASTER 2nd Generation.
P113
Drive model
0 - 29
[
¶¶¶
]
Read-only parameter; indicates the Vector model number according to the type
range indicated by P112.
P113
P112 = 6
P112 = 7
P113
P112 = 6
P112 = 7
0
MMV12
MDV550/2
15
MMV110/2
MDV3000/3
1
MMV25
MDV750/2
16
MMV150/2
MDV3700/3
2
MMV37
MDV1100/2
17
MMV220/2
MDV4500/3
3
MMV55
MDV1500/2
18
MMV300/2
MDV5500/3
4
MMV75
MDV1850/2
19
MMV400/2
MDV7500/3
5
MMV110
MDV2200/2
20
MMV37/3
MDV220/4
6
MMV150
MDV3000/2
21
MMV55/3
MDV400/4
7
MMV220
MDV3700/2
22
MMV75/3
MDV550/4
8
MMV300
MDV4500/2
23
MMV110/3
MDV750/4
24
MMV150/3
MDV1100/4
10
MMV12/2
MDV750/3
25
MMV220/3
MDV1500/4
11
MMV25/2
MDV1100/3
26
MMV300/3
MDV1850/4
12
MMV37/2
MDV1500/3
27
MMV400/3
MDV2200/4
13
MMV55/2
MDV1850/3
28
MMV550/3
MDV3000/4
14
MMV75/2
MDV2200/3
29
MMV750/3
MDV3700/4
P121
Enable/disable RUN button
0 - 1
[1]
0 =
RUN button disabled
1 =
RUN button enabled (only possible if P007 = 1)
P122
Enable/disable
FORWARD/REVERSE button
0 - 1
[1]
0 =
FORWARD/REVERSE button disabled
1 =
FORWARD/REVERSE button enabled (only possible if P007 = 1)
P123
Enable/disable JOG button
0 - 1
[1]
0 =
JOG button disabled
1 =
JOG button enabled (only possible if P007 = 1)
P124
Enable/disable
D
and
Ñ
buttons
0 - 1
[1]
0 =
D
and
Ñ
buttons disabled
1 =
D
and
Ñ
buttons enabled (only possible if P007 = 1)
Note:
This applies for frequency adjustment only. The buttons can still be
used to change parameter values.
P125
Reverse direction inhibit
0 - 1
[1]
This parameter can be used to prevent the inverter from running a motor in the
reverse direction.
0 =
Reverse direction disabled. Inhibits reverse commands from ALL sources
(e.g. front panel, digital, analogue, etc.). All negative RUN commands (e.g.
ON left, JOG left, REVERSE, etc.) result in FORWARD rotation. Any
negative result of setpoint addition is clipped at 0 Hz.
1 =
Normal operation. Forward and reverse direction of rotation allowed.
P128
Fan switch-off delay time (seconds)
(MMV only)
0 - 600
[120]
Time taken for the fan to switch off following an OFF command.
P131
Frequency setpoint (Hz)
0.00-650.00
[-]
P132
Motor current (A)
0.0 - 300.0
[-]
P133
Motor torque (% nominal torque)
0 - 250
[-]
Read-only parameters. These are copies of the values stored in P001 but can
be accessed directly via the serial link.
P134
DC link voltage (V)
0 - 1000
[-]